category: Power Distribution Equipment
reference price:¥$175.00 - $195.00
Name: industrial pdu socket
Model:YKDPZ-A
Website:www.ykpowersupply.com
Regards as rack mount PDU , We can customized all kind of PDU according to your request
Main introduction of rack mount PDU
YKDPZ-A is a DC power distribution system module with 19inch standard structure, small size , easy to install and use. There is A-B 2chs input, multi-channels output (max 18chs). Visual-aural alarm when there is failure. LED display running status
This equipment has excellent performance and reliable quality. It’s widely used in Telecom, BTS, Mobile, Unicom, electric power, army, public security, etc.
Specification of rack mount PDU
Item |
Technical specification |
Rated voltage |
-48VDC/24VDC/220VDC/110VDC or -48VAC/24VAC/220VAC/110VAC can be optional |
Insulation resistance |
≥30MΩ |
Insulating intensity |
Input—housing AC1000V,50Hz,1minute Output-housing AC1000V,50Hz,1minute |
Input channels |
2 channels DC-48V,10A,16A, 32A, 63A ,100A,125A circuit breaker/air switch can be optional |
Output channels |
1-8 channels DC-48V,10A, 16A, 32A, 63A,100A,125A (optional) output current capacity |
Alarm |
Visual-aural alarm signal. When there is any channel is failed, Red LED ON and buzzer sounds. |
Working environment |
Working temperature 0°C~40°C Related humility ≤90% (+20±5°C) atmospheric pressure 70Kpa~106Kpa |
Dimension |
L*D*H(mm) 485 mm *135 mm *80 mm |
Weight |
3.0Kg |
Packing |
510 mm *150 mm *125mm, 3.5kg |
rack mount PDU
This DC power distribution system module can display the running status of all the channels. When there is failure or break, Red LED ON and buzzer sounds and giving the alarming signal to third party system for alarming
If you want to stop alarm, please press “SA” button. If there are others failure right now, there will be no alarm.
When there is failure again, RED LED still ON, and it will not OFF until the failure is eliminated and switch is turn on
Installation and connection of rack mount PDU
1. Install
Easy and simple install. Standard 3.0U structure, can install in the standard 19 inch cabinet.
2. Connection
All the connection is on the rear panel.
Please connect with the anode, cathode and grounding as required. Please tighten the connection screw and nut. Connection must be steady and reliable to reduce the resistance.
3. Notes
Please don’t change or replace any wiring or air switch etc inside the dc power distribution system module. If you want to change or replay, please contact with manufactures.
Notes
Must be engineer or technician or electrician to install the DC power distribution system !
Our Service/Why Choose US
Any Question be arise , please do not hesiate to Contact US
------------------------------