1.Product Description

The watt-hour meter can be divided into DC watt-hour meter and AC watt-hour meter according to its circuit. According to its phase line, AC energy meter can be divided into single-phase energy meter, three-phase three-wire energy meter and three-phase four-wire energy meter.

According to its working principle, electric energy meters can be divided into electrical mechanical energy meters and electronic energy meters (also known as static energy meters, solid-state energy meters). Electrical mechanical watt-hour meter is used in AC circuit as a common energy measuring instrument, the most commonly used one is inductive watt-hour meter. Electronic watt-hour meters can be divided into all-electronic watt-hour meters and electromechanical watt-hour meters.

 

2.Specification

 

StandardIEC62053-21; IEC62052-11
ProductSingle Phase Three Wire Static Watt Hour Meter
Model CET-D238-A(Mrchanical step register) 
CET-D238-B(LCD)
DisplayMechanical step register or LCD
Rated Voltage110-130V; 220-240V
Rated Current10(50)A; 5(60)A;10(60)A;15(60)A;20(80)A;10(100)A;20(100)A;30(100)A
Frequency50Hz or 60Hz
Accuracy Class1
Power Consumption<2W/10VA
Start Current0.004ib
Constant800-3200imp/kwh
Pulse Output passive pulse, pulse width is 80+5ms
Optional Functionbattery for display when power off

 

StandardIEC62053-21; IEC61036, ANSI
ProductSingle Phase Round Socket Type Static Watt Hour Meter
Model CET-D238-C(LCD)
DisplayLCD  (Single Phase Two Wire or Single Phase Three Wire)
Rated Voltage110-130V; 220-240V
Rated Current10(60)A; 10(100)A; 15(100)A; 30(100)A; 30(200)A; CL100; CL200
Frequency60Hz
Accuracy Class1
Power Consumption<2W/10VA
Start Current0.004ib
Constant800-3200imp/kwh
Pulse Output passive pulse, pulse width is 80+5ms
Optional Functionbattery for display when power off

 

StandardIEC62053-21; IEC62052-11
ProductThree Phase Static Watt Hour Meter
Model CET-S238-A(Mechanical step register )                                   
CET-S238-B(LCD)
DisplayMechanical step register or LCD
Rated VoltageThree Phase Four Wire(3x57.7/100V; 3x127/220V; 3x120/208V; 3x220/380V; 3x230/400V; 3x240/415V)                                                                                                             
Three Phase Three Wire(3x220V; 3x380V; 3x400V; 3x415V; 3x100V)         
 Two Phase Three Wire(2x120/208V;  2x127/220V)
Rated Current1.5(6)A; 5(30)A; 10(40)A; 5(60)A; 20(80)A; 10(100)A; 20(100)A; 30(100)A
Frequency50Hz or  60Hz
Accuracy Class1
Power Consumption<2W/10VA
Start Current0.004ib
Constant800-3200imp/kwh
Pulse Output passive pulse, pulse width is 80+5ms

 

StandardIEC62053-21; IEC61036
ProductSingle Phase Din Rail Type Watt Hour Meter
Model A. DDS238-1P(Mechanical step register )                                                 
B. DDS238LCD-1P without RS485                                                                          
C. DDS238LCD-1P with RS485
PhaseSingle Phase
Rated Voltage110-130V; 220-240V
Rated Current5(32)A; 5(30)A
Frequency50Hz or 60Hz
Accuracy Class1
Power Consumption<2W/10VA 
Basic Function1. Mechanical step register 5+1;  LCD 6+1(default) or 5+2                                               
2. Bi-directional total active energy measurement, reverse active energy measure in the total active energy. 
3. Pulse LED indicates working of meter, pulse output with optical coupling isolation.    
4. 35mm din rail installation.
Optional FunctionFor LCD type,  can choose the RS485 comminication port.


 

StandardIEC62053-21; IEC61036
ProductDin Rail Type Watt Hour Meter
Model A. DDS238-2P(Mechanical step register )                                                 
B. DDS238LCD-2P without RS485                                                                          
C. DDS238LCD-2P with RS485
PhaseSingle Phase two wire
Rated Voltage110-130V; 220-240V
Rated Current5(65)A; 5(30)A; 10(40)A; 5(60)A
Frequency50Hz or 60Hz
Accuracy Class1
Power Consumption<2W/10VA
Basic Function1. Mechanical step register 5+1;  LCD 6+1(default) or 5+2                                               
2. Bi-directional total active energy measurement, reverse active energy measure in the total active energy. 
3. Pulse LED indicates working of meter, pulse output with optical coupling isolation. 
4. Power LED indicates power on/off.                                                      
5. 35mm din rail installation.                                                                                    
6. The meter display real voltage, real current, real power, real power factor, real frequency, real time and date.
Optional FunctionFor LCD type, can choose the RS485 comminication port.

StandardIEC62053-21; IEC61036
ProductDin Rail Type Multi-function Watt Hour Meter
Model A. DDS238-4P(Mechanical step register )                                                 
B. DDS238LCD-4P without RS485                                                                          
C. DDS238LCD-4P with RS485
PhaseSingle Phase two wire
Rated Voltage110-130V; 220-240V
Rated Current1.5(6)A; 5(30)A; 10(40)A; 5(60)A; 20(80)A; 20(100)A; 30(100)A
Frequency50Hz or 60Hz
Accuracy Class1
Power Consumption<2W/10VA
Basic Function1. Mechanical step register 5+1;  LCD 6+1(default) or 5+2
2. Bi-directional total active energy measurement, reverse active energy measure in the total active energy.        
3. Pulse LED indicates working of meter, pulse output with optical coupling isolation.   
4. Power LED indicates power on/off
5. 35mm din rail installation. 
6. The meter display real voltage, real current, real power, real power factor, real frequency, real time and date.
Optional FunctionFor LCD type,  can choose the RS485 comminication port.

 

 

StandardIEC62053-21; IEC62052-11
ProductSingle Phase Two Wire Static Watt Hour Meter
Model CET-RC12-A(Mechanical step register )                                                   
CET-RC12-B(LCD)
DisplayMechanical step register or LCD
Rated Voltage110-130V; 220-240V
Rated Current10(50)A; 5(60)A; 10(60)A; 15(60)A; 20(80)A; 10(100)A; 
Frequency50Hz or 60Hz
Accuracy Class1
Power Consumption<2W/10VA
Start Current0.004ib
Constant800-3200imp/kwh
Pulse Output passive pulse, pulse width is 80+5ms

 

3.Functions

This meter is featured with wide load, high accuracy, high reliability, high sensitivity, straight error curve, low power consumption, small volume, light weight, energy saving, material saving, direct register display, etc.

 

4.Details

DDS238 SERIES:

 

5.More Products

                                                 

6.Application

 

7.Packaging&Shipping

 

 

8.Certificate

 

 

9.FAQ

Q1: Can I have a sample for testing?

A: Yes, we can offer free sample, but you should afford the shipping cost.

Q2: Can I add my logo on the products?

A: Yes, OEM and ODM are available for us.

Q3: How can I get the after-service?

A: We will send you the free spare parts if the problems caused by us. If the products cannot be repaired, we will send

you new free quantity together with next order.

Q4: Do you have inspection procedures for products?

A: our products100% self-inspection and testing before packing. 

Q5: Can I have a visit to your factory before the order?

A: Sure, welcome to visit our factory.

Here is our factory address:  #7 Tongyi Industrial Area, Zhongshan City, Guzhen

Our factory is near Guangzhou airport, and we can pick you up in the airport,   Hotel booking service is available.

Q6: How about delivery time of the order?

A: 15-20 days after getting deposit.

Q7: How about payment terms?

A:  20%-30% deposit, the rest payment balance against B/L. If have regular order and good order quantity, we can give

delay payment.

 

10.Contact Us