1.Product Description

The watt-hour meter can be divided into DC watt-hour meter and AC watt-hour meter according to its circuit. According to its phase line, AC energy meter can be divided into single-phase energy meter, three-phase three-wire energy meter and three-phase four-wire energy meter.

According to its working principle, electric energy meters can be divided into electrical mechanical energy meters and electronic energy meters (also known as static energy meters, solid-state energy meters). Electrical mechanical watt-hour meter is used in AC circuit as a common energy measuring instrument, the most commonly used one is inductive watt-hour meter. Electronic watt-hour meters can be divided into all-electronic watt-hour meters and electromechanical watt-hour meters. 

 

2.Specification

StandardIEC  62053-21 , GB/T17215.321
Productsingle-phase electronic type watt-hour meter
Model  CET-DDS3666
DisplayRegister, LCD and LED
Rated Voltage220 or 240V
Rated Current1.5(6), 2.5(10), 5(20), 5(30), 10(40), 10(60), 15(60), 20(80), 30(100)
Frequency50Hz or 60Hz
Accuracy Class1 or 2

StandardIEC  62053-21 
ProductSingle-phase Electronic Prepayment Watt-hour Meter
Model  CET-DDSY3666
DisplayLCD, LED
Power Dissipation≤2W,10VA
Rated Current5(20), 10(40), 15(60)
Frequency50Hz or 60Hz
Accuracy Class1 or 2

 

StandardIEC  62053-21 
Productsingle-phase electronic type watt-hour meter
Model  CET-DDSY366-1P
Reference Voltage 220V-230V
Power Dissipation≤2W(10VA)
Rated Current1.5(6)A,5(20)A, 10(40)A, 15(60)A,20(80)A,30(100)A
Frequency50Hz or 60Hz
Accuracy Class1 or 2

StandardIEC  62053-21 
ProductSingle Phase Electronic Watt-hour Meter
Model  CET-DDSY366-2P
Reference Voltage 220V-230V
Power Dissipation≤2W(10VA)
Rated Current1.5(6)A,5(20)A,5(32)A,5(65)A, 10(40)A, 15(60)A
Frequency50Hz or 60Hz
Accuracy Class1

 

 

StandardIEC  62053-21 
Productsingle-phase electronic type watt-hour meter
Model  CET-DDSY366-4P
Reference Voltage 220V-230V
Power Dissipation≤2W(10VA)
Rated Current1.5(6)A,5(20)A, 10(40)A, 15(60)A,20(80)A,30(100)A
Frequency50Hz or 60Hz
Accuracy Class1 or 2

StandardIEC  62053-21 
Productthree-phase four wire watt-hour meter
Model  CET-DTS366-4P
Reference Voltage 3*220V/380V,3*230V/400V,3*240/415V
Power Dissipation≤2W(10VA)
Rated Current3*1.5(6)A,3*2.5(10)A,3*5(20)A, 3*10(60)A,3* 15(60)A,3*20(80)A
Frequency50Hz or 60Hz
Accuracy Class1

 

StandardIEC  62053-21 
Productthree-phase three/four wire watt-hour meter
Model  CET-DTS366-7P
Reference Voltage 3*100V,3*380V,3*57.7/100V,3*220V/380V
Power Dissipation≤2W(10VA)
Rated Current3*1.5(6)A,3*2.5(10)A,3*5(20)A, 3*10(60)A,3* 15(60)A,3*20(80)A,3*30(100)A
Frequency50Hz or 60Hz
Accuracy Class1 or 2

 

StandardIEC  62053-21 
Productsingle-phase electronic type watt-hour meter
Model  CET-DDS36
Reference Voltage220V-230V
Power Dissipation≤2W(5VA)
Rated Current1.5(6)A,5(20)A,10(40)A,15(60)A,20(80)A,30(100)A
Frequency50Hz or 60Hz
Accuracy Class1 or 2


StandardIEC  62053-21 
Productsingle-phase electronic watt-hour meter
Model  CET-DDSR
Reference Voltage120V-240V
Power Dissipation≤2W(5VA)
Rated Current1.5(6)A,5(20)A,10(40)A,15(60)A,20(80)A,30(100)A
Frequency50Hz or 60Hz
Accuracy Class1

 

3.Funcions & Features

Stable measuring accuracy, general speaking, it would be free from effect of frequency, temperature, voltage or high order harmonic. After leaving the factory, it is unnecessary to make further regulation to the complete machine, it is allowable to prolong the verification period, which sharply reduces the testing and inspection work of power department, it has obviously advantage in reliability when comparing with other similar products.

Bi-directional measuring function, it is able to measure out the forward and reverse active energy accurately, and the reverse active energy would also be reckoned in forward value.

It is able to reserve the data of electric quantity permanently without help of standby battery.

The register will be driven by single chip directly, preventing pulse-loss phenomenon during power on or off, which guarantees consistency of meter reading data and register indicating value, avoids unnecessary dissension due to inconsistency of data.

Adoption of optical coupling isolated passive pulse output interface .

This meter is featured with wide load, high accuracy, high reliability, high sensitivity, straight error curve, low power consumption, small volume, light weight, energy saving, material saving, direct register display, etc.

 

 

4.Installation & Connection

        DDS366

 

 

 

 

5.More Products

                                                      

6.Application

 

 

7.Packaging&Shipping

 

8.Certificate

 

 

9.FAQ

Q1: Can I have a sample for testing?

A: Yes, we can offer free sample, but you should afford the shipping cost.

Q2: Can I add my logo on the products?

A: Yes, OEM and ODM are available for us.

Q3: How can I get the after-service?

A: We will send you the free spare parts if the problems caused by us. If the products cannot be repaired, we will send

you new free quantity together with next order.

Q4: Do you have inspection procedures for products?

A: our products100% self-inspection and testing before packing. 

Q5: Can I have a visit to your factory before the order?

A: Sure, welcome to visit our factory.

Here is our factory address:  #7 Tongyi Industrial Area, Zhongshan City, Guzhen

Our factory is near Guangzhou airport, and we can pick you up in the airport,   Hotel booking service is available.

Q6: How about delivery time of the order?

A: 15-20 days after getting deposit.

Q7: How about payment terms?

A:  20%-30% deposit, the rest payment balance against B/L. If have regular order and good order quantity, we can give

delay payment.

 

10.Contact Us 

 TEL:0086-21-64783375

 FAX:0086-21-54240680

Send us an inquiry for more information