TPP Series Inverter/Chargder Specifications for 3-15KW models | ||||||||||||
Model | TPP 3KW | TPP 6KW | TPP 9KW | TPP 12KW | TPP 15KW | |||||||
Output | Continuous Output Power | 3000W | 6000W | 9000W | 12000W | 15000W | ||||||
Surge Rating(20s) | 9000W | 18000W | 27000W | 36000W | 45000W | |||||||
Capable of Starting Electric Motor | 3HP | 4.5HP | 6HP | 9HP | 12HP | |||||||
Unbalance Load Acceptable | 100% | |||||||||||
DC Input Voltage | 12/24/48V | 12/24/48V | 12/24/48Vdc | 12/24/48V | 24/48V | |||||||
Waveform | Pure Sine wave or Same as input (by pass mode) | |||||||||||
Nominal Efficiency | 89% | |||||||||||
Line Mode Efficiency | >95% | |||||||||||
Power Factor | 0.9-1.0 | |||||||||||
Connection mode | 3-phase 4-wire system+Gnd | |||||||||||
Output voltage rating | 3AC/N Y-207/400Vac | |||||||||||
Output phase voltage | 120/230V | 120/230V | 120/230V | 120/230V | 120/230V | |||||||
Output Voltage Regulation | ±10% RMS | |||||||||||
Output Frequency | 50/60Hz ± 0.3Hz | |||||||||||
Short Circuit Protection | Yes, Current Limit Function (Fault after 60ms) | |||||||||||
Typical transfer Time | Typical 6-8ms,10ms(Max) | |||||||||||
THD | < 3%(Linear Load) | |||||||||||
Nominal Input Voltage | 24/48Vdc | |||||||||||
Minimum Start Voltage | 42Vdc / 44Vdc | |||||||||||
Low Battery Alarm | 42Vdc / 44Vdc | |||||||||||
Low Battery Trip | 40.0Vdc /42.0Vdc | |||||||||||
High Voltage Alarm & Fault | 64.0Vdc | |||||||||||
High DC Input Recovery | 62.0Vdc | |||||||||||
Low Battery Voltage Recover | 52.0Vdc | |||||||||||
Search Mode | < 100 W when Power Saver On | |||||||||||
Other | Communication | RS232/485/CAN | ||||||||||
Display | LED+LCD |
TPP Series Inverter/Chargder Specifications for 18-45KW models | ||||||||||||
Model | TPP 18KW | TPP 24KW | TPP 30KW | TPP 36KW | TPP 45KW | |||||||
Output | Continuous Output Power | 18000W | 24000W | 30000W | 36000W | 45000W | ||||||
Surge Rating(20s) | 54000W | 72000W | 90000W | 108000W | 135000W | |||||||
Capable of Starting Electric Motor | 18HP | 24HP | 30HP | 36HP | 45HP | |||||||
Unbalance Load Acceptable | 100% | |||||||||||
DC Input Voltage | 24/48V | 48V | 48V | 48V | 48V | |||||||
Waveform | Pure Sine wave or Same as input (by pass mode) | |||||||||||
Nominal Efficiency | 89% | |||||||||||
Line Mode Efficiency | >95% | |||||||||||
Power Factor | 0.9-1.0 | |||||||||||
Connection mode | 3-phase 4-wire system+Gnd | |||||||||||
Output voltage rating | 3AC/N Y-207/400Vac | |||||||||||
Output phase voltage | 120/230V | 230V | 230V | 230V | 230V | |||||||
Output Voltage Regulation | ±10% RMS | |||||||||||
Output Frequency | 50/60Hz ± 0.3Hz | |||||||||||
Short Circuit Protection | Yes, Current Limit Function (Fault after 60ms) | |||||||||||
Typical transfer Time | Typical 6-8ms,10ms(Max) | |||||||||||
THD | < 3%(Linear Load) | |||||||||||
Nominal Input Voltage | 24/48Vdc | |||||||||||
Minimum Start Voltage | 42Vdc / 44Vdc | |||||||||||
Low Battery Alarm | 42Vdc / 44Vdc | |||||||||||
Low Battery Trip | 40.0Vdc /42.0Vdc | |||||||||||
High Voltage Alarm & Fault | 64.0Vdc | |||||||||||
High DC Input Recovery | 62.0Vdc | |||||||||||
Low Battery Voltage Recover | 52.0Vdc | |||||||||||
Search Mode | < 100 W when Power Saver On | |||||||||||
Other | Communication | RS232/485/CAN | ||||||||||
Display | LED+LCD |