USFULL 1P 2P 3P 4 Pole circuit breaker manufacturer ac mcb DZ47 switch

category: Circuit Breakers

reference price:¥$0.64 - $1.10

Purchase quantity
- +

Zhejiang Fullwill Electric Co., Ltd.

Mr. Group
Product details Company introduction
Parameter information

Technical Parameters:  
Related Current(A) Pole Number Related Working 
Voltage(V)
Breaking Capacity Tripping Curve
1, 2, 3, 4, 5, 6, 10, 16,
20, 25, 32, 40, 50, 63
1, 2 230/240 3/4.5(KA) B, C, D
1, 2 230/400, 240/415
2, 3, 4 400/415
Remark:  
1. Type B is generally used for lighting, C type for general household appliances (market mainstream), D type motor protection.
2. Electrical life: standard 6,000 times, we can reach 10,000 times.
    Mechanical life: standard 20,000 times (off-on), but working without electricity can be achieved 100,000 times. 
3. Heat resistance: category 2 (temperature 55°C, relative humidity 95%).
Current Release Character Diagram:  
Test current
(A)
Rated current
(A)
Requested time Result Start station Remark
1.13In All t>=1h Don’t trip Cool  
1.45In All t<1h trip Heat Current ascends the requested value stably in 5s
2.55In In<=32A 1s<t<60s trip Cool Auxiliary switch closed, power is on 
2.55In In>32A 1s<t<120s trip Cool Auxiliary switch closed, power is on 
5In(Cmode) All t>=0.1s Don’t trip Cool Auxiliary switch closed, power is on 
10In(Cmode) All t<0.1s  trip Cool Auxiliary switch closed, power is on 
10(Dmode) All t>=0.1s  Don’t trip Cool Auxiliary switch closed, power is on 
14In(Dmode) All t<0.1s trip Cool Auxiliary switch closed, power is on 

1. What is a miniature circuit breaker?
It can connect, carry and break the current under normal circuit conditions. Under specified abnormal conditions (such as short-circuit current), A mechanical switching device that can also switch on, carry-fixed time and break current.
With current overload protection and line short circuit protection, the rated current does not exceed 125A 
2. How to choose the right circuit breaker?
The circuit breaker is generally selected at 1.5 times the normal working current.
3. What is the difference between 2P and 1P+N of circuit breaker?

Prepresents the number of poles, N represents the zero line, 2P represents that both poles of the miniature circuit

breaker have thermal and magnetic protection functions, and the width is 36mm;
And 1P+N, only the hot wire thermal magnetic protection function, the N pole has no thermal magnetic

protection function, but it will be disconnected from the live wire at the same time, the width is 18mm;
Therefore, 1P+N is more economical than 2P, and it also has higher safety.

It is suitable for applications with small current such as lighting circuits.

4. How to get a quote?
Please contact our sales staff and leave a message that you need which poles, current, quantity, EXW/FOB or CIF, 
we will reply you as soon as we receive the message.
5. Feedback policy.

a. We maintain high standards of excellence and strive for 100% customer satisfaction!

Feedback is very important to us.
b. If you have any question for the products you received, please contact us in time and

we will try our best to solve the problems and make you satisfied.
c. Please give us the positive feedback.