Categories

China suppliers three phase 380V 75kw AC drive/ speed Controller /VFD/VSD/ ac variable frequency drive inverter for AC motor

Purchase quantity
- +

Shenzhen Invt Electric Co., Ltd.

Mr. Group
Product details Company introduction
Parameter information
Product Description
Specification
Function
Specification
Power input
Input voltage (V)
AC 3PH 200V~240V Rated voltage: 220V AC 3PH 380V~480V Rated voltage: 460V
AC 3PH 520V~600V Rated voltage: 575V
Allowable Voltage Fluctuation
-15%~+10%
Input current (A)
Refer to the rated value
Input frequency (Hz)
50Hz or 60HzAllowed range: 47~63Hz
Power output
Output voltage (V)
0~input voltage
Output current (A)
Refer to the rated value
Output power (kW)
Refer to the rated value
Output frequency (Hz)
0~400Hz
Technical control feature
Control mode
SVPWM, sensorless vector control
Motor type
Asynchronous motor and permanent magnet synchronous motor
Adjustable-speed ratio
Asynchronous motor 1:200 (SVC) synchronous motor 1:20 (SVC)
Speed control accuracy
±0.2% (sensorless vector control)
Speed fluctuation
± 0.3% (sensorless vector control)
Torque response
<20ms(sensorless vector control)
Torque control accuracy
10% (sensorless vector control)
Starting torque
Asynchronous motor: 0.25Hz/150% (SVC) Synchronous motor: 2.5 Hz/150% (SVC)
Overload capability
G type: 150% of rated current: 1 minute
180% of rated current: 10 seconds
200% of rated current: 1 second
P type:
120% of rated current: 1 minute
180% of rated current: 10 seconds
180% of rated current: 1 second
Running control feature
Frequency setting method
Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLC setting, PID setting,
MODBUS communication setting, PROFIBUS communication setting. Switch between the combination and single setting channel.
Auto-adjustment of the voltage
Keep constant voltage automatically when the grid voltage transients
Fault protection
Provide more than 30 fault protection functions: overcurrent, overvoltage, undervoltage, overheating, phase loss and overload,
etc.
Restart after rotating speed tracking
Smooth starting of the rotating motor
Peripheral interface
Terminal analog input resolution
≤ 20mV
Terminal switch input resolution
≤ 2ms
Analog input
2 (AI1, AI2) 0~10V/0~20mA and 1 (AI3) -10~10V
Analog output
2 (AO1, AO2) 0~10V /0~20mA
Digital input
8 common inputs, the max frequency: 1kHz, internalimpedance: 3.3kΩ;
1 high speed input, the max frequency: 50kHz
Digital output
1high speed pulse output, the max frequency: 50kHz; 1 Y terminal open collector output
Relay output
2 programmable relay outputs RO1A NO, RO1B NC, RO1C common terminal
RO2A NO, RO2B NC, RO2C common terminal
Contactor capability:3A/AC250V, 1A/DC30V
Others
Mountable method
Wall and flange mounting
Temperature of the running environment
-10~50℃, derate 1% for every additional 1℃ above 40℃
Average non-fault time
2 years (25℃ ambient temperature)
Cooling
Air-cooling
Braking unit
Built-in for inverters of 220V(≤15kW) and 460V(G-type≤30kW, P-type≤37kW),
optional for inverters of 220V(18.5~55kW) ,
460V(G-type≥37kW, P-type≥45kW), and 575V
EMC filter
The inverters of 460V have built-in C3 filters: meet the degree requirement of IEC61800-3 C3
Overvoltage category
For input voltage 220-240V: transient surge suppression shall be installed on the line side of this equipment and shall be rated
220V (phase to ground), 220V (phase to phase), suitable for overvoltage categoryⅢ, and shall provide protection for a rated
impulse withstand voltage peak of 4kV. For input voltage 323-480V: transient surge suppression shall be installed on the line side
of this equipment and shall be rated 480V (phase to ground), 480V (phase to phase), suitable for overvoltage category Ⅲ, and shall
provide protection for a rated impulse withstand voltage peak of 6kV. For input voltage 323-480V: transient surge suppression
shall be installed on the line side of this equipment and shall be rated 575V (phase to ground), 575V (phase to phase), suitable
for overvoltage category Ⅲ, and shall provide protection for a rated impulse withstand voltage peak of 6kV.
Packing & Delivery
Company Profile
FAQ
Q1: Are you the original factory of INVT? A:Yes. We recommend that you buy from our official channel to protect your right. Q2: What is the delivery time? A: It depends on the quantity of your order. Our dealers also have stocks locally. Q3: How to choose the right model? A: Tell us your need, and our sales will help you. Q4: What is your aftersales service? A: There are 80+ overseas distributors and 20+ worldwide warranty service centers offering service support locally. Q5: How to contact INVT? A: Email: alibaba@invt.com.cn Web:www.invt.com Facebook:https://www.facebook.com/invtofficial/ Twitter:https://twitter.com/invtgroup LinkedIn:https://www.linkedin.com/company/1825886/admin/ YouTube:https://www.youtube.com/user/invtgroup