Categories

Acrel din rail-mounted solar dc energy meter for pv power station

category: Energy Meters

Purchase quantity
- +

Acrel E-Business (shanghai) Co., Ltd.

Ms. Xue
Product details Company introduction
Parameter information
DJSF1352-RN rail-mounted DC power meter

Product Description

Characteristic

DJSF1352-RN rail-mounted DC power meter with double DC input channels, designed for telecommunications base
stations, DC charging piles, solar photovoltaic and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system.The actual use of the site, you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, computers to form a measurement and control system.
The meter can have infrared communication interface and RS-485 communication interface, and supports Modbus-RTU protocol and DLT645-97 (07) protocol at the same time.The meter can have relay alarm output and digital input
function;You can set the ratio, alarm, and communication through the meter panel keys according to different requirements.The meter can have event recording of switch (Modbus protocol), programming and event setting records (645 protocol), instantaneous and timing freeze function of data (645 protocol), maximum and minimum value recording function of voltage and current power.
Specification
Technical parameters
Index
Input
Nominal value
Voltage input range
Current input
DC0-1000V 
Shunt:0-75mV
Hall sensor:0-20mA,4-20mA,0-   5V,0-10V and so on.
Overload
1.2 times rated(continuous);2 times rated/1 second;
Power consumption
Voltage:≤0.2VA, Current:≤0.1VA
Accuracy class
class 1
Function
Display
8-bit segment LCD screen (LCD)
Communication Interface
RS485, infrared
Communication protocol
Modbus-RTU,DL/T 645-2007
Switch
Switch output
2 Relay outputs, 2A/30VDC or 2A/250VAC
Switch input
2 dry contact inputs
Pulse output
A second pulse output, a energy pulse output
See the SYS->PLUS display in the meter menu settings. For example: The meter displays 100, which is 100imp/kWH
Power Supply
Voltage range
AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
Power consumption
≤ 3W
Power frequency withstand voltage
Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output
3kV/1min Power supply // Relay output // Voltage input // Current input 3kV/1min Pulse output // Communication interface // Switch
input 2kV/1min
Insulation resistance
≥ 40M Ω
Average barrier-free working hours
≥50000h
Environment
Temperature
Normal operating temperature: -25 °C ~ +55 °C; Limit working temperature: -40 °C ~ +70 °C; Storage temperature: -40℃~+70℃
Humidity
≤93%RH, no condensation, no corrosive gas
Altitude
≤2500m
Installation

Product installation

The meter is designed by standard DIN35mm rail mounted.


Terminals and wiring

Note: The second DC input channel and DI and DO functions are optional. When the current input mode is current shunt input:

More Type
Type
Function
FOB Shanghai(USD)


DJSF1352-RN
1. DC voltage, current, power measurement
2. Forward and reverse energy measurement
3. RS485 and infraredCommunication
4. Time sharing and multi rate energy measurement
5. SOE Sequence Of Event record


103.6
DJSF1352-RN/K
On the basis of DJSF1352-RN, add the switch function(2DI/2DO)
124.4
DJSF1352-RN/D
On the basis of DJSF1352-RN, add the second channel of energy measurement
124.4
DJSF1352-RN/KD
On the basis of DJSF1352-RN, add the second channel of energy measurement and switch function(2DI/2DO)
145
Packing & Delivery
Company Profie