Categories

96*48mm digital Power Factor Meter W watt meter

category: Power Meters

Purchase quantity
- +

Zhejiang Huapu Instrument Co., Ltd.

Mr. Zj
Product details Company introduction
Parameter information

Product Description

Summarization

Product name

 Digital 9648 power meter
Display type Red LED
 Size 96*48mm
 Accuracy

± 0.5% range ± 1 character (active power);

± 1% range ± 1 character (reactive power)

Aux. power supply  AC 220V 
 Weight  200g
 Overload   Continuous: 1.2 times, instantaneous: 2 times/1s
 Measuring range  0 ~9999MW
Resolution tatio Max 1W ( 1 var ), decimal point will shift automatcally
 Working temperature -10~55°C

 

 Basic Specification

Technical parameter Index value

Accuracy of

measurement

Current / voltage ±0.5% FS

Active/reactive/apparent power

±0.5% FS
Frequency ±0.1Hz
Power factor ±0.01PF
Active energy Grade 1.0
Reactive energy Grade 2.0
Power supply Range AC/DC 85~264V
Power consumption < 5VA
Input         Network 3P3W, 3P4W
Voltage    Rated voltage AC 57.7V, 100V, 220V, 380V
Overload Continuous: 1.2 times (if exceed, display HHHH), instantaneous: 2 times/1s
Power consumption <1VA (each phase)
Impedance >1kΩ/V
Current   Rated current AC 1A ,5A
Overload  Continuous: 1.2 times (if exceed, display HHHH), instantaneous: 10 times/5s
Impedance  <20mW (each phase)
Frequency range   45 ~ 65Hz
 Output            Energypulse   Output mode   1-channel collector open coupling pulse output
 Pulse constant 3200imp/kWh

 RS-485

Communication 

 Agreement  MODBUS_RTU
 Baud ratio  1200, 2400, 4800, 9600, 19200

Analog

 quantity  

 Channel number  1-channel or 3-channel (some types can support 4-channel)
 Output mode  0~20mA, 4~20mA ,can be programmable
 Load capacity  ≤500Ω

Switching

value  

 Channel number  1-channel or 3-channel (some types can support 4-channel)
 Output method  The upper and lower limits use the same relay (No contacts) to output
 Contact capacity  AC 240V/1A
 Switching value input   1 or 3-channel (some types can support 4-channel) passive contact
 Safety   Insulation resistance   Among the input, output, power supply and shell >20MΩ
 Withstand voltage   Among the input, output and power supply ≥ 2kV 50Hz/1min
 Environment   Temperature   Working: -10~55℃, storage: -25~70℃
 Humidity   ≤85%RH, places without condensation corrosive gas situation

 

Contour & Installation Size     unit:  mm

Meter Size Surface Size Shell Size Installation Size
Width (D) Height (H) Width (D) Height (H) Depth (L) Width (D) Height (H)
9648 96 48 90 43 88 92 45

 

Application