Welcome to wziep.com!
Welcome to wziep.com!
category: Motor Starters
reference price:¥$318.60 - $330.80
Item | Specification |
Power supply | AC220V/380V/660V±15% |
Power frequency | 50/60Hz |
Adaptive Motor | Squirrel-cage three-phase asynchronous motor |
Starting times | It is recommended not to exceed 20 times per hour |
Control mode | 1) Operation panel control; 2) Operation panel +external control; 3) External control ; 4) External control+ COM control ; 5) Operation panel +external+ COM control; 6) Operation panel + COM control; 7) COM control ; 8) No start or stop operation; |
Start Mode | 1) Current-limiting start; 2) Voltage ramp start; 3) Torque control +current-limiting to start; 4) Torque control +voltage ramp to start; 5) Current ramp to start; 6) Voltage current-limiting double closed-loop start; |
Stop Mode | 1) Soft stop; 2) Free stop; |
1) Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) Starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over-voltage protection for power voltage; 11) Protection for fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals; | |
Protection Class | IP00,IP20 |
Cooling Pattern | Natural wind cooling |
Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. |
Below 2000M. Rise the rate power when the altitude is more than 2000M. Ambient Temperature -25+45°C Ambient Humidity 95%(20°C±5°C) Vibration<0.5G |
Model | Power | Current | External Dimension(mm) | N.W | ||||||||
220V | 380V | 480V | (kW) | (A) | H1 | W1 | D | (KG) | ||||
-- | 5.5 | 5.5 | 5.5 | 11 | 270 | 146 | 160 | <5 | ||||
-- | 7.5 | 7.5 | 7.5 | 15 | 270 | 146 | 160 | <5 | ||||
5.5 | 11 | 11 | 5.5/11 | 23 | 270 | 146 | 160 | <5 | ||||
7.5 | 15 | 15 | 7.5/11 | 30 | 270 | 146 | 160 | <5 | ||||
-- | 18 | 18 | 18.5 | 37 | 270 | 146 | 160 | <5 | ||||
11 | 22 | 22 | 11/22 | 43 | 270 | 146 | 160 | <5 | ||||
15 | 30 | 30 | 15/30 | 60 | 270 | 146 | 160 | <5 | ||||
18 | 37 | 37 | 18.5/37 | 75 | 270 | 146 | 160 | <5 | ||||
22 | 45 | 45 | 22/45 | 90 | 270 | 146 | 160 | <5 | ||||
30 | 55 | 55 | 30/55 | 110 | 270 | 146 | 160 | <5 | ||||
37 | 75 | 75 | 37/75 | 150 | 270 | 146 | 160 | <5 | ||||
45 | 90 | 90 | 45/90 | 180 | 525 | 257 | 198 | <21 | ||||
55 | 115 | 115 | 55/115 | 230 | 525 | 257 | 198 | <21 | ||||
-- | 132 | 132 | 132 | 264 | 525 | 257 | 198 | <21 | ||||
75 | 160 | 160 | 75/160 | 320 | 525 | 257 | 198 | <21 | ||||
90 | 185 | 185 | 90/185 | 370 | 525 | 257 | 198 | <21 | ||||
100 | 200 | 200 | 100/200 | 400 | 525 | 257 | 198 | <21 | ||||
132 | 250 | 250 | 132/250 | 500 | 525 | 257 | 198 | <21 | ||||
160 | 280 | 280 | 160/280 | 560 | 525 | 257 | 198 | <21 | ||||
185 | 320 | 320 | 185/320 | 640 | 570 | 290 | 245 | <25 | ||||
-- | 355 | 355 | 355 | 640 | 570 | 290 | 245 | <25 | ||||
200 | 400 | 400 | 200/400 | 800 | 590 | 330 | 245 | <30 | ||||
220 | 450 | 450 | 220/450 | 900 | 590 | 330 | 245 | <30 | ||||
250 | 500 | 500 | 250/500 | 1000 | 665 | 410 | 245 | <42 | ||||
320 | 600 | 600 | 315/600 | 1200 | 665 | 410 | 245 | <42 |
The loading | Voltage ramp start time(s) | Voltage ramp stop time(s) | Initial voltage | Voltage ramp (Current limit) | Current limit to start |
Bill mill machine | 20 | 6 | 60% | 400% | 350% |
Fan | 26 | 4 | 30% | 400% | 350% |
Centrifugal | 16 | 20 | 40% | 400% | 250% |
Piston compressor | 16 | 4 | 40% | 400% | 300% |
hoister | 16 | 10 | 60% | 400% | 350% |
Stirring machine | 16 | 2 | 50% | 400% | 300% |
Breaker | 16 | 10 | 50% | 400% | 350% |
Screw compressor | 16 | 2 | 40% | 400% | 300% |
Rotating conveyor | 20 | 10 | 40% | 400% | 200% |
Light load | 16 | 2 | 30% | 400% | 300% |
Convey belt | 20 | 10 | 40% | 400% | 250% |
Heat pump | 16 | 20 | 40% | 400% | 300% |