Categories

Wide use of 12V high voltage dc contactor 30amp for battery switching and circuit protection

category: Contactors

reference price:¥$5.00 - $25.00

Purchase quantity
- +

Wenzhou Xinchi International Trade Co., Ltd.

Ms. Tan
Product details Company introduction
Parameter information
Product Description
Application
Product parameters
Product number
 JSR30A—1G—X—SH
JSR50A—1G—X—SH
Contact form
SH
SH
Contact material
Cu alloy
Cu alloy
Contact resistance
≤1.9mΩ(12VDC/10A)
2500VAC/min
Maximum switching voltage
1200VDC
1200VDC
Maximum switching current
250A/320V
250A/320V
Overload cut
250A at 320VDC, 1 time
250A at 320VDC, 1 time
Mechanical life
2x105time
2x105time
Electrical life
1×104time(400V,30A)
1×104time(400V,30A)
Standard Voltage
12VDC
24 VDC
48 VDC
Operating Voltage
9.6~13.2VDC
19.2~26.9 VDC
38.4~52.8 VDC
Maximum voltage
15VDC
30 VDC
60 VDC
Maximum pull-in voltage
9.6 VDC
19.2 VDC
38.4 VDC
Insulation resistance
≥100MΩ/500VDC
Dielectric withstand voltage
2500VAC/min
Company Profile
Wenzhou Xinchi International Trade Co., Ltd is a group company,There are four branch companies subordinate to it. Registered
trademark is "suntree".

Main Products:DC-Fuse, Solar system parts,Solar Panel/Inverter/Cable/Connector, AC&DC Circuit Breakers, MCCB, ATS auto transfer
switch, Isolator switch, Waterproof distribution box,DC combiner box, etc.

Quality &Standards:Products are producted per ISO9001:2008, IEC60947, IEC60898,CB, SAA, TUV,CE,SONCAP,ROHS, Nemko, PCT, CCC etc.
Main markets:Australia,New Zealand,&other worldwide markets.

Business strategies &Characristic:Stability, expertise and technological innovation are the corner stones of our company's
business strategy.
We are trying to develop XinChi into a world-class Electrical manufactures

The end of the life of the contactor, that is, the insulation of the insulated instrument at 500V, the insulation strength between
the output ends is as low as 50 megohms.
Packing and Shipping
Precautions
1. To touch the load terminal when the contactor is energized, be careful of the risk of electric shock. 2. When testing the
control loop and non-metallic materials for withstand voltage, disconnect the load voltage. 3. Do not install the product in a
place with a strong magnetic field (transformer or magnet) or an object near heat radiation. 4. Do not dip the debris and oil to
the main lead-out terminal, and the external lead terminal is in reliable contact with the main lead-out terminal, otherwise the
terminal will be heated. Very powerful, causing the connecting cable to melt. 5. When performing the operating voltage test, do
not slowly increase the voltage. Please drive the coil by the step power supply method. 6. The stud tightening torque of each
mounting part is controlled within the specified range. The nut locking torque of the load contact screw mounting part is
GB/T3098.10 requirements. The stud torque of the contactor mounting part is 3-6N.m. 7. In case of falling outside the relay and
being impacted, please do not use it in principle.