Welcome to wziep.com!
Welcome to wziep.com!
category: Parameter Measuring Instrument
reference price:¥$922.48 - $1,085.27
High Voltage Line Phase Detecting | ||
Detector Power Supply | DC4.5V,LR6X3PCS | |
Phase Detecting Mode | 1. Contact mode phase detecting: circuit line below 35kV 2. Non-Contact mode phase detecting: when 10KV< line voltage≤35kV,can phase detecting on the cable insulation skin; when the line voltage > 35kV, must adopt non-contact mode to testing | |
Phase Detecting Voltage | 10V~500kV | |
Phase Detecting Distance | 200 meters | |
Detector Size | 130mm×65mm×45mm | |
Detector Weight | 2PCS,total weight 400g | |
Insulation Rod Length | Max dia.:Φ45mm;Length:contraction state 1000mm;stretched state:4500mm | |
Ring Main Unit Technical Specification | ||
Detector Power Supply | DC6V,button battery LR44X4PCS | |
Phase Detecting Mode | Contact mode phase detecting | |
Phase Detecting Voltage | AC 5V~600V | |
Phase Detecting Distance | 30 meters | |
Detector Size | 120mm×54mm×30mm | |
Detector Weight | 2PCS,total weight 260g | |
Metalclad Withdraw Switchgear Technical Specification | ||
Detector Power Supply | DC6V,button battery LR44X4PCS | |
Phase Detecting Mode | Non-Contact mode phase detecting | |
Phase Detecting Voltage | 10KV / 35KV | |
Phase Detecting Distance | 20meters | |
Detector Size | 80mm×46mm×26mm | |
Detector Weight | 6PCS,total weight 420g | |
Others Technical Specifications | ||
Host Power Supply | Host: DC 9V,alkaline battery LR6 X 5PCS | |
LCD Size | 3.5 inch colorful screen; display area: 71mm×53mm | |
Host Size | 195mm×100mm×45mm | |
Host Weight | 350g | |
Phase Qualitative | Same phase:-20°~20°;Out of phase: 100°~140° and 220°~260° | |
Phase Range & Accuracy | 0°~360°;Accuracy:≤±8 °;Resolution :1° | |
Frequency Range & Accuracy | 45.0Hz~65.0Hz;Accuracy:≤±2Hz;Resolution :0.1Hz | |
Transmitting Frequency | 433MHz, 315MHz | |
Phase Indication | Vectogram and digital display | |
Power Indication | The detector with the green power indicator | |
Electricity Testing Indication | “Du-du-du” buzzer sound | |
Voltage Grade Display Range | 0.4kV~35kV | |
Display Speed | 2 times/second | |
Data Storage | 200 groups(Power down or replace the battery will not lose data) | |
Automatic Shutdown | 15 minutes after boot up, the meter shuts down automatically without any operation | |
Battery Voltage | When battery voltage is lower than 8.1V±0.1V,low battery voltage symbol will display and remind to replace battery. The measurement data still are also accurate at this time. | |
Rated Current | Detector:30mA max;Host:150mA max | |
Instrument Weight | About 6.5KG (include the insulation rod) | |
Instrument Case Size | 1050mmX310mmX100mm | |
Insulation Test | The insulation rod stretched to both ends:AC 220kV/rms; Host, detector:AC3700V/rms(between exposed metal and plastic shell) | |
External Interference | No extra-strong electromagnetic field; No 433MHz, 315MHz same frequency interference | |
Working Temperature And Humidity | -10℃~40℃;below 80%rh | |
Store Temperature And Humidity | -10℃~60℃;below 70%rh | |
Protection Level | IP63 | |
Suitable Safety Standard | It meets the standard of GB13398-92, GB311.1-311.6-8, 3DL408-91, and the national power industry standard requestment (general technical conditions DL/T 971-2017 for 1kV ~ 35kV portable nuclear phase devices for live working). | |
Meet standard IEC61481-A2;2004;IEC 61243-1 ed.2:2003 | ||
Insulation Test | Host, detector : AC3700V/rms(between the exposure metal and plastic shell) | |
Accessories | Host: 1PCS, Line detector :2PCS, Probe: 2PCS, Probe hook: 2PCS, Line detector calibration line: 1PCS, Insulation rod: 2PCS, Ring main unit probe: 2PCS, Alligator clip: 2PCS, Metalclad withdraw switchgear calibration line:1PCS, button battery: 22PCS; ,USB Data Cable:1PCS , Cloth Bag: 1PCS, Screwdriver 1PCS(replace battery) |