Categories

Modern Voltmeter 0-100 V Analog Voltmeter 220V Dc Voltmeter 600Volt Voltage Meter

category: Voltage Meters

reference price:¥$25.50 - $36.50

Purchase quantity
- +

Toky Electrical Co., Ltd.

Ms. Liu
Product details Company introduction
Parameter information

Modern Voltmeter 0-100 V Analog Voltmeter 220V Dc Voltmeter 600Volt Voltage Meter

Product Description
Model Alarm Analog RS485 DI input Input range Code
DL8-IRC18V600 2 loops 4~20mA Yes Yes IN1:6V,IN2:60V,IN3:600V B0490DL01
DL8-IRC18V200 2 loops 4~20mA Yes Yes IN1:2V,IN2:20V,IN3:200V B0490DL01
DL8-IRC18V100 2 loops 4~20mA Yes Yes IN1:1V,IN2:10V,IN3:100V B0490DL01
DL8-IRC18A2 2 loops 4~20mA Yes Yes IN1:2A,IN2:0.2A,IN3:0.02A B0490DL01
DL8-IRC18AACT 2 loops 4~20mA Yes Yes IN1:5A(AC) B0490DL01
DL8-IRC18DACT 2 loops 4~20mA Yes Yes IN1:75mV(DC) B0490DL01
DL8-RC18V600 2 loops No Yes Yes IN1:6V,IN2:60V,IN3:600V B0410DL01
DL8-RC18V200 2 loops No Yes Yes IN1:2V,IN2:20V,IN3:200V B0410DL01
DL8-RC18V100 2 loops No Yes Yes IN1:1V,IN2:10V,IN3:100V B0410DL01
DL8-RC18A2 2 loops No Yes Yes IN1:2A,IN2:0.2A,IN3:0.02A B0410DL01
DL8-RC18AACT 2 loops No Yes Yes IN1:5A(AC) B0410DL01
DL8-RC18DACT 2 loops No Yes Yes IN1:75mV(DC) B0410DL01
DL8-IRC10V600 2 loops 4~20mA No No IN1:6V,IN2:60V,IN3:600V B0370DL01
DL8-IRC10V200 2 loops 4~20mA No No IN1:2V,IN2:20V,IN3:200V B0370DL01
DL8-IRC10V100 2 loops 4~20mA No No IN1:1V,IN2:10V,IN3:100V B0370DL01
DL8-IRC10A2 2 loops 4~20mA No No IN1:2A,IN2:0.2A,IN3:0.02A B0370DL01
DL8-IRC10AACT 2 loops 4~20mA No No IN1:5A(AC) B0370DL01
DL8-IRC10DACT 2 loops 4~20mA No No IN1:75mV(DC) B0370DL01
DL8-RC10V600 2 loops No No No IN1:6V,IN2:60V,IN3:600V B0280DL01
DL8-RC10V200 2 loops No No No IN1:2V,IN2:20V,IN3:200V B0280DL01
DL8-RC10V100 2 loops No No No IN1:1V,IN2:10V,IN3:100V B0280DL01
DL8-RC10A2 2 loops No No No IN1:2A,IN2:0.2A,IN3:0.02A B0280DL01
DL8-RC10AACT 2 loops No No No IN1:5A(AC) B0280DL01
DL8-RC10DACT 2 loops No No No IN1:75mV(DC) B0280DL01
DL8-IV600 No 4~20mA No No IN1:6V,IN2:60V,IN3:600V B0300DL01
DL8-IV200 No 4~20mA No No IN1:2V,IN2:20V,IN3:200V B0300DL01
DL8-IV100 No 4~20mA No No IN1:1V,IN2:10V,IN3:100V B0300DL01
DL8-IA2 No 4~20mA No No IN1:2A,IN2:0.2A,IN3:0.02A B0300DL01
DL8-IAACT No 4~20mA No No IN1:5A(AC) B0300DL01
DL8-IDACT No 4~20mA No No IN1:75mV(DC) B0300DL01
DL8-V600 No No No No IN1:6V,IN2:60V,IN3:600V B0215DL01
DL8-V200 No No No No IN1:2V,IN2:20V,IN3:200V B0215DL01
DL8-V100 No No No No IN1:1V,IN2:10V,IN3:100V B0215DL01
DL8-A2 No No No No IN1:2A,IN2:0.2A,IN3:0.02A B0215DL01
DL8-DACT No No No No IN1:75mV(DC) B0215DL01

 

Power supply 100~240V AC/DC(85-265V)
Measurement accuracy (>2000)±0.5%F.S±3digits @ 25±3℃ Measuring temperature drift < 500PPM
Resolution Minimum unit display value of default range or 12bits
AC Frequency

AC measuring frequency range:45~400Hz

measuring accuracy range: 50~100Hz

Relay capacity AC 250V /1A rated load life > 100000 times
Power consumption < 6VA
Environment

In door, temperature: 0~50℃ no condensation,

humidity: <85%RH,altitude<2000m

Storage environment -10~60℃, no condensation
Switching input No power dry contact input Signal voltage≤DC 24V
Current output DC 4~20mA Load<500Ω Temperature drift 300PPM
Communication RS485 port Modbus-RTU procotol, can be connected up to max 30 units.
Insulation resistance Input, output, power VS meter cover >20MΩ
ESD IEC/EN61000-4-2 Contact ±4KV /Air ±8KV perf.Criteria B
Pulse train anti-interference IEC/EN61000-4-4   ±2KV perf.Criteria B
Surge immunity IEC/EN61000-4-5   ±2KV perf.Criteria B

Voltage drop & short

interruption immunity

IEC/EN61000-4-29  0%~70% perf.Criteria B

Isolation withstand

voltage

Signal input, output, power: 2000VAC 1min
Weight About 400g
Cover material The shell and panel frame PC/ABS (Flame Class UL94V-0)
Panel material PET(F150/F200)
Power failure memory 10 years, times of writing: 1 million times
Panel Protection level IP65 (IEC60529)
Safety Standard IEC61010-1 Overvoltage category Ⅱ,pollution level 2,levelⅡ(Enhanced insulation)
Product Overviews

Company Information

 

Related Products

 

FAQ

FAQ

Q1.Can you produce according to the samples or drawings? 
Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.

 

Q2.What is your terms of payment? 
Usually,we accept T/T, irrevocable L/C at sight. For regular orders, Terms of payment 30% deposit, full payment before delivery the goods.

 

Q3.What is the lead time?  
For standard models, lead time is about 3~5 days after order confirmed and payment received.

For OEM orders, the delivery is about 2~3 weeks after data confirmed and payment received.

 

Q4.What is your terms of packing?  
Under TOKY brand, the standard packing is 1pc item in a colour box or brown inner box, then into standard export carton.

For OEM order, usually 1pc item in a brown inner box, then into standard export carton.

 

Q5.What is your terms of delivery?     
We accept EXW,FOB,CIF,etc. You can choose the one which is the most convenient or cost effective for you.

 

Q6.How to solve the quality problems after sales?   
Take photos or videos of the problems and send to us. 
We will make a satisfied solution for you within 24 hours after we confirm the problems.

 

Q7.Do you have any MOQ limit for the order?

Low MOQ, 1pc for sample checking is available.

 

Q8.Is it OK to print my logo on the product?
Yes, OEM service is available.
Please confirm with our sales team formally before production and confirm the design firstly based on our sample.

 

Q9.Are you manufacturer or trading company?
We are manufacturer for over 30 years. Welcome to visit our factory at anytime.

 

Return to homepage