Welcome to wziep.com!
Welcome to wziep.com!
category: Resistance Meters
reference price:¥$370.00
Model contrast | ||||||
Model | DW236 | DW236A | DW236B | |||
The resistance range | 0.01Q500Q | 0.01 Q- 1200Q | 0.01Q-1500Q | |||
Current range | No | 0.00mA-20.0A | 0.00mA-40.0A | |||
Voltage range | No | No | 0.0V-100V | |||
Precision of resistance | ±1%±0.01Q | ±1%±0.01Q | ±1%±0.01Q | |||
Resistance resolution | 0.001 Q | 0.001 Q | 0.001 Q | |||
Accuracy of current | No | ±2%±1mA | ±2%±1mA | |||
Current resolution | No | 0.01mA | 0.01 mA |
Technical Specification | ||
Function | Ground resistant test, Loop resistance test, leakage current test | |
Resistance Range | 0.01Ω-1200Ω ; Resolution: 0.001Ω; Accuracy: ±1%±0.01Ω | |
Current Range | 0.00mA-20.0A ; Resolution:0.01mA; Accuracy: ±2%±1mA | |
Power Supply | DC6V Alkaline Dry Battery (1.5V LR6 X 4) | |
Measurement Method | Mutual induction | |
Clamp Diameter | 55mm×32mm | |
Clock Function | Have | |
Ω+A Synchronized display | Ω+A same screen display | |
Display Mode | 4-digit LCD display, black screen design | |
LCD Dimension | 46mm×29mm | |
Meter Dimension | W/T/H: 85mm×58mmx285mm | |
Sampling Speed | About 2 times/second | |
USB interface | With USB interface, software monitoring, storage data can be uploaded to the computer, save the print | |
Communication Line | USB communication line 1 | |
Data Storage | 500 Groups, the symbol “MEM” gives indication, “FULL” mark will flash to indicate the memory has been full | |
Data Review | "MR" symbol indication when reviewing data | |
Overflow Display | Exceed measurement range overflow function: “OL ” symbol display | |
Interference Test | Automatic identify interference signal, "NOISE" symbol indication when the interference current is large | |
Alarm Function | Alarm when the measured value exceeds the alarm setting value | |
Battery Voltage | Real-time display of battery power, reminding timely charging when battery voltage is low | |
Automatic shut-down | "APO" instruction, automatic shutdown after 5 minutes boot | |
Power Consumption | 50MA Max | |
Weight | Instrument: 1180g (with battery) | |
Working Temperature and Humidity | -10°C~40C; below 80% rh | |
Insulation Resistance | 20Ω or more (500V between circuit and outside) | |
Pressure Resistance | AC 3700V/rms(between circuit and outside) | |
Suitable for Safety Regulations | IEC61010-1(CAT III 300V, CAT IV 150V, Pollution Degree 2); IEC61010-031; IEC61557-1 (grounding resistance) | |
Accessories | ||
Meter | 1PC | |
Meter box | 1PC | |
5# battery | 4PCS(the battery is not included) | |
Monitoring Software CD | 1PC | |
Calibration ring | 1PC | |
USB communication line | 1PC | |
Manual, certificate | 1SET |