Welcome to wziep.com!
Welcome to wziep.com!
category: Resistance Meters
reference price:¥$481.00
Range and Accuracy error | ||||||||
Measurement function | Measurement range | Accuracy | Resolution | |||||
Grounding resistance (R) | 0.00Ω~30.00Ω | ±2%rdg±5dgt (remark 1) | 0.01Ω | |||||
30.0Ω~300.0Ω | ±2%rdg±3dgt | 0.1Ω | ||||||
300Ω~3000Ω | ±2%rdg±3dgt | 1Ω | ||||||
3.00kΩ~30.00kΩ | ±2%rdg±3dgt | 10Ω | ||||||
Soil resistivity (ρ) | 0.00Ωm~99.99Ωm | ρ=2πaR (remark 2) | 0.01Ωm | |||||
100.0Ωm~999.9Ωm | 0.1Ωm | |||||||
1000Ωm~9999Ωm | 1Ωm | |||||||
10.00kΩm~99.99kΩm | 10Ωm | |||||||
100.0kΩm~999.9kΩm | 100Ωm | |||||||
1000kΩm~9999kΩm | 1kΩm | |||||||
Grounding voltage | AC 0.00~100.0V | ±2%rdg±3dgt | 0.01V |
General specification | ||
Function | Two three four-wire measure grounding resistance, soil resistivity; Ground voltage, AC voltage measurement | |
Ambient temperature and humidity | 23℃±5℃,below 75%rh | |
Power | DC 6V 4.5Ah lead-acid battery lasts more than 100 hours standby | |
Interference voltage | <20V (should be avoided) | |
Interference current | <2A (should be avoided) | |
Measure R electrode spacing | a>5d | |
Measured electrode spacing | a>20h | |
Auxiliary ground resistance | Reference condition <100Ω, working condition <5kΩ | |
Range | Grounding resistance: 0.00Ω~30.00kΩ | |
Soil resistivity: 0.00Ωm~9999kΩm | ||
Grounding voltage: 0.00V~100.0V | ||
measurement mode | Precise four-wire, three-wire measurement, simple two-wire measurement | |
Measurement methods | Grounding resistance: rated current change pole method Soil resistivity: four-pole method Ground Voltage: Average Rectification(between S-ES interface) | |
Test frequency | 128Hz | |
Short circuit test current | > 20mA (Sine Wave) | |
Open circuit test voltage | AC 28V max | |
Electrode spacing range | Can be set 1m ~ 100m | |
Change gear | fully automatic shifting 0.00Ω ~ 30.00kΩ | |
fully automatic shifting 0.00 Ωm~9000kΩm | ||
Backlight | Controllable gray screen backlight, suitable for use in dim places | |
Display mode | 4-bit large LCD display, gray screen backlight | |
Measurement instructions | LED flashing indicator during measurement | |
LCD size | 111mm×68mm | |
LCD display field | 108mm×65mm | |
Instrument size | L/W/H:277.2mm×227.5mm×153mm | |
Standard test line length | 4 strips:red 15m,black 15m, yellow 10m,green 10m each one | |
Simple test line | 2strips:yellow 1.6m,green 1.6m each one | |
Auxiliary Grounding rod | 4PCS:φ10mm×200mm | |
Measure time | Ground voltage:about 3 times/sec; | |
grounding resistance,soil resistivity: about 7 seconds/time | ||
Line voltage | Measurement below AC100V (ground voltage measurement function cannot be used to measure commercial power) | |
USB interface | With USB interface | |
Communication Line | One USB communication line, 1.5m long | |
Data storage | 500 groups, "MEM" storage indicates, flashing "FULL" symbol indicates that the memory is full | |
Data review | Data review function: "MR" symbol display | |
Overflow display | Over-range overflow function: "OL" symbol display | |
Interference test | Automatic identification of interference signals, "NOISE" symbol indication when the interference voltage is higher than 5V | |
Auxiliary grounding test | With auxiliary ground resistance test function, 0.00KΩ ~ 30kΩ (Rh max = 3kΩ +100R <50kΩ; Rs max = 3kΩ +100R <50kΩ) | |
Alarm function | Alarm when the measured value exceeds the alarm setting value | |
Battery voltage | Real-time display of battery power, reminding timely charging when battery voltage is low | |
Automatic Shutdown | “APO” Indicates, automatic Shutdown After 15 Minutes | |
Power consumption | Standby: 40mA Max(Backlight off) | |
Turn on backlight: about 43mA | ||
measuring:75mA Max(Backlight off) | ||
Weight | Instrument: 2450(including battery) | |
Test lines:1300g | ||
Auxiliary grounding rod: 850g(4PCS) | ||
Working temperature and humidity | -10℃~40℃;below 80%rh | |
Storage temperature and humidity | -20℃~60℃;below 70%rh | |
Overload protection | Grounding resistance:AC 280V/3 seconds between H-E and S-ES ports | |
Insulation resistance | More than 20MΩ(500V between circuit and housing) | |
Pressure resistance | AC 3700V/rms(between circuit and housing) | |
Electromagnetic properties | IEC61326(EMC) | |
Suitable for safety regulations | IEC61010-1(CAT Ⅲ 300V,CAT IV 150V,pollution level 2); IEC61010-031; IEC61557-1(grounding resistance); IEC61557-5(soil resistivity); JJG 366-2004. |