Categories

400KVA 630KVA 10/0.4 KV Outdoor Compact Metal-clad Distribution Transformer Substation / Mobile Electrical Box Substation

category: Power Distribution Equipment

reference price:¥$20,000.00

Purchase quantity
- +

Yueqing Aibeiken Electric Co., Ltd.

Ms. Li
Product details Company introduction
Parameter information
Products Description
ZGSQ-12/0.4 pre-installed substation is a domestic American box transformer. As an important power supply unit in the wireline distribution network, the product is a complete set of pre-installed products, which integrates high-voltage control, protection, power transformation and distribution equipment, and is widely used in urban and rural distribution networks. The product places the high voltage load switch and high voltage flame breaker in the transformer oil, and has two structure forms: sharing box with the transformer body or separating the box. The oil tank adopts fully sealed structure, equipped with oil temperature gauge, oil level gauge, pressure gauge, pressure release valve, oil discharge valve and other components to monitor the transformer operation condition. The product is divided into ring network type, terminal type and power supply type power supply square.In order to make this product more suitable for the actual requirements of the power grid of various countries, the company has pushed the plug-type dry fuse, fuse fuse does not affect the performance of transformer oil. According to the complexity of low pressure feedout requirements, ZGSQ-12/0.4 products are divided into three shell forms: standard type, enhanced type and integrated type, so that users and design units can be more flexible and more economical in the selection.
Product Paramenters



Standard
IEC 62271-1
IEC 62271-202
IEC60067
IEC61439
No. of medium voltage compartment
1
No. of transformer compartment
1
No. of low Voltage compartment
1
Medium voltage compartment
Protection spec
IP43
Service Rated voltage
15KV
Voltage variation of the system
±10%
Permisible maximum operating voltage
17.5KV
Permisible maximum Equipment voltage
24Kv
RMU(2 incomming + 1 outgoing)
Load break switch with earthing switch
2
Type
frequency
50Hz
Power frequency withstand voltage(RMS)
38KV
Rated lightning impulse withstand voltage (Peak)
95KV
Rated current
630A
Rated short time withstand current for 1s
25KA
Vacume circuit breaker with earthing switch and isolator
1
Nominal voltage
15KV
rated frequency
50Hz
Power frequency withstand voltage(RMS)
38KV
Rated lightning impulse withstand voltage (Peak)
95KV
Rated short time withstand current for 1s
25KA
Low Voltage compartment
Protection spec
IP23
Nominal voltage
0.4KV
rated frequency
50Hz
Power frequency withstand voltage(RMS)
3KV for 1 minute
Rated current
1250A
Rated short time current rating
50KA
CT quantity
3
CT voltage rating
380V
CT Ratio
1250/5A
Freq.
50Hz
Burden
15VA
Ammeter quantity
3
ammeter current range
0-1250A
Voltmeter with selector switch quantity
1
voltage range
0-500V
Tansformer compartment
Protection spec
IP23
Cooling method
ONAN
No of Phases
3
Standard
IEC 60354
Freq.
50Hz
Rated contineous power on HV side
630KVA
Rated contineous power on LV side
630KVA
Rate voltage on HV side
15Kv
Rate voltage on LV side
0.4Kv
Vector group
Dyn5
No load loss at rated voltage and frequency
<=0.6KW
Full load loss
<=6.5KW
Color
Gray
Thickness of surface treatment
140µm
short circuit impedance at principal tapping
4%
ability to withstand unbalanced load
>=9%
Transformer tank
steel
Core type
steel
type
wire or coil
HV winding material
copper
Power frequency withstand voltage(RMS)
38KV
Rated lightning impulse withstand voltage (Peak)
95KV
LV winding material
copper
Power frequency withstand voltage(RMS)
3KV
Rated lightning impulse withstand voltage (Peak)
6KV

THE USE OF CONDITIONS

1. Ambient temperature: maximum temperature +40°C, minimum temperature -30P; 2. Altitude: 1000m; 3 wind speed: quite 34m/s (not more than 700Pa); 4. Humidity: the average daily relative humidity is not more than 95%, and the average monthly relative humidity is not more than 95%; 5. Shock proof: horizontal acceleration is no more than 0.4m/s2; The vertical acceleration is not greater than 0.15m/s2; 6. Slope of installation site: no more than 3。; 7. Installation environment: the surrounding air is not obviously polluted by corrosive and flammable gases, and the installation site is not violently shaken; 8. If you order this product beyond the above conditions, you can negotiate with our company.
Company Profile
FAQ
Q1. What are your terms of packing?
A: Generally, we pack our goods in neutral white boxes and brown cartons. If you have legally registered patent, we can pack the goods in your branded boxes after getting your authorization letters.
Q2. What are your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.
Q3. What are your terms of delivery?
A: EXW, FOB, CFR, CIF, DDU.
Q4. How about your delivery time?
A: Generally, it will take 15 to 30 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.
Q5. Can you produce according to the samples?
A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.
Q6. What are your sample policy?
A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.
Q7. Do you test all your goods before delivery?
A: Yes, we have 100% test before delivery
Q8: How do you make our business long-term and good relationship?
A:1. We keep good quality and competitive price to ensure our customers benefit ;
2. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.