equipment and has stronger load capacity.
Welcome to wziep.com!
Welcome to wziep.com!
category: Industrial Power Supply
reference price:¥$25,150.00 - $26,350.00
Product Name | Shenzhen factory cost Industrial frequency online three phase UPS 10kva 60kva 100kva 150kva 200kva 300kva 400kva | ||
Capacity | 400KVA / 320 KW | ||
Single-phase Max current input (A) | 609 A | ||
Topology | Double Conversion Online UPS | ||
Working Principle | On-line power supply, static bypass switch (uninterrupted switch), double conversion technology | ||
AC Input | Phase | Three Phase + N + G | |
Voltage Range | 380VAC ±25% | ||
Frequency Range | 50Hz ±10%, 60Hz ±10% | ||
Voltage Hamonic distortion | < 10% | ||
Soft start | 0-100% 5 sec. | ||
The bypass | Phase | Three Phase + N + G | |
Voltage Range | 380VAC ±15% | ||
Frequency Range | 50Hz ±10%, 60Hz ±10% | ||
Conversion time (Inverter / Bypass) | 0 ms | ||
The Battery | Number of battery unit | 30 knots / 12V series | |
battery voltage | 360V | ||
Maximum discharge current (A) | 1015 A | ||
Float charging Voltage | 405V (After 3 months, the battery needs to be equalized and the floating charge voltage is 435v) | ||
Charging current (A) | 1A - 50A (according to battery capacity you used) | ||
The Inverter | Power factor of the load | 0.8 (0.9 optional) | |
Phase | Three-phase + N + G | ||
Nominal Voltage | 380VAC ±1% (The stead-stage load), 380VAC ±3% (The load fluctuation) | ||
Nominal Frequency | 50Hz ±10%, 60Hz ±10% (Power supply by battery) | ||
Frequency stability when not in sync | <±0.05% | ||
When the frequency stability synctronization | <±5% | ||
Output wave form | Sine Wave | ||
Total harmonic distortion | Linear load <2%, The nonlinear load <4% | ||
Dynamic load voltage transients | <5% (from 0 to 100% or more) | ||
Transient recovery time | <10 ms (±5%) | ||
Unbalanced Voltage | <±1% (Balance the load voltage), <±3% (Unbalanced load) | ||
Overload capacity | Overload for 10 minutes, later turn to the bypass, 125% 150% overload lasts 1 minutes and then byp0ass; | ||
The inverter efficiency and load by 100% | 95% | ||
The System Structure | Total efficiency of 100% load | 91%, 95% ECO | |
Computer communication interface | Rs232, (Rs485, Network remote monitoring software | ||
Operating temperature | 0-40°C | ||
Relative Humidity | 0-90% without any condensation | ||
Running high | <1500 m (each additional 100 meters power fell by 1%, the highest 4000 meters) | ||
Cooling way | Forced ventilation (temperature control) | ||
Noise (db) | <65 | ||
The body color | As pictures showed | ||
The input cable | From the ports at the bottom or on the back | ||
Easy to maintain | On / about / in front of the plane can be opened | ||
Input device | Terminal row | ||
The output device | Terminal row | ||
HMI | LCD DISPLAY | Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status | |
Standards Communication Interface | 1. RS232 PORT | ||
Optional Extension Card | 2. NMC Card: Support remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown 3. MODBUS Card, 4. USB Card | ||
Size (D x W x H cm) | 95 x 130 x 180 cm | ||
Est. net weight | 2500 kgs | ||
Related accessories for choice | Rs485, wave board, ntework management system, battery testing system, lighting protection devices,... ...etc. | ||
Welcome your customized designs and requriements. |