Acrel APM830 Multifunction Energy Meter electrical EMS energy monitoring system power management system

Purchase quantity
- +

Acrel Electric Co., Ltd.

Ms. Fan
Product details Company introduction
Parameter information
Overview
APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with international advanced technology. APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network. This series of meters use a modular design, with a rich function of the external DI / DO module, AI / AO module, event recording (SOE) module with T-Flash (TF) card, network communication module, Temperature and humidity measurement module, can achieve full power measurement of electrical circuit and monitoring of switch status, Dual RS485 with Ethernet interface can realize data copying of RS485 master station, eliminating the need for data switching exchange. PROFIBUS-DP interface can realize high-speed data transmission and networking function.
Appearance
Characteristics

Communication

Standard: RS485(Modbus-RTU) Optional: Profibus(Profibus-DP), Ethernet(Modbus-TCP, HTTP, DHCP).

Display

LCD display U, I, P, Q, PF, kWh and other energy consumption, power measurement, harmonic content.

Rated U and I

Voltage:AC 100V、110V、400V、690V;Current:AC 1A, 5A, support 2 mm2 line access.
Function
Accuracy
Voltage、current and power:class 0.5S
Active power:class 0.5S
Reactive power: class 2
Frequency
Range:45-65Hz
Auxiliary power supply
AC/DC 85V~265V or AC/DC 115~415V
Pulse output
Output mode: Optocoupler pulse with open collector;
Pulse constant:4000(5A)、8000(1A) imp/kWh;
Consumption
Voltage:Power consumption:<0.5VA;
Current:Power consumption:< 0.5VA;
Auxiliary power supply:power consumption≤15VA


Installation

Panel mounted

Dimension(L*W*H)
Panel size(L×W): 96*96mm
Cutout(L×W): 92*92mm

Relay
3A/AC250V 3A/DC30V

Starting current
0.1%
Type and Specification

Function
APM800
(class 0.5s)
APM801
(class 0.2s)
APM810
(class 0.5s)
Measured parameters
Total electrical measurement
Four-quadrant energy

Pulse output of energy

Pulse output of active/reactive energy






Demand
Three-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)





Extreme value statistics
Extremum of current, line voltage, phase voltage, active power, reactive power, apparent power, power factor, frequency, total
harmonic of current, total harmonic of voltage in this month and last month (including time stamp)














Power quality
Unbalance of current, line voltage, phase voltage

Voltage phase angle, current phase angle

Voltage current phase Angle

Total (odd, even) harmonic content of voltage and current

×
×
Harmonic content of voltage and current (2-63 times)①

×
×
Voltage crest factor

×
×
Telephone waveform factor

×
×
Current K-factor

×
×
Alarm records
A total of 66 kinds of alarm types, each type can record the most recent 16 alarm records, support extended records by TF card




Event log
Record the most recent 128 event records, support extended records by TF card




Communication
Modbus protocol

I/O
2 digital inputs + 2 digital outputs (2DI+2DO)









Extensions
MD82
8 digital inputs + 2 digital outputs with changeover contacts (8DI+2DO)


MLOG
TF card storage (alarm records, event records, electrical parameters and energy timing records, etc.)



MA84
8 analog inputs (class 0.5) + 4 analog outputs (class 0.5) (8AI+4AO)
MCM
1 RS485/Modbus-RTU, support master mode or slave mode
MCP
1 Profibus-DP
MCE
1 Ethernet, support Modbus-TCP, http, SMTP, DHCP protocol

MTH
4 ways of temperature measurement, 1 way of temperature and humidity control
Note ①: Accuracy of 2~42 times harmonic measurement in the frequency range of 45~65Hz is 1%, accuracy of 43~63 times harmonic measurement in frequency 50Hz is 2%.

Function
APM830
(class 0.5s)


Measured parameters
Total electrical measurement
Four-quadrant energy

Complex rate electric energy
Internal temperature measurement of instrument
Pulse output of energy
Total active power, total reactive power, total apparent power pulse output, second pulse, etc



Demand
Three-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)



Extreme value statistics
Extremum of current, line voltage, phase voltage, active power, reactive power, apparent power, power factor, frequency, total
harmonic of current, total harmonic of voltage in this month and last month (including time stamp)








Power quality
Unbalance of current, line voltage, phase voltage

Voltage phase angle, current phase angle

Total (odd, even) harmonic content of voltage and current

Harmonic content of voltage and current (2-63 times)①


Voltage crest factor


Telephone waveform factor


Current K-factor


Vector


Voltage and current waveform
Fundamental voltage and current
Alarm records
A total of 66 kinds of alarm types, each type can record the most recent 16 alarm records, support extended records by TF card




Event log
Record the most recent 128 event records, support extended records by TF card


Transient record, record up to 800 transient waveform records, support TF card expansion record
Communication
Modbus-RTU protocol

DL / T 645 - 2007 protocol (support freeze function)
I/O
2 digital inputs + 2 digital outputs (2DI+2DO)

Multiple rate
The multi-rate energy statistics include total, sharp, peak, flat, valley and near-month multi-rate electricity








Extensions
MD82
8 digital inputs + 2 digital outputs with changeover contacts (8DI+2DO)


MLOG
TF card storage (alarm records, event records, electrical parameters and energy timing records, etc.)

MA84
8 analog inputs (class 0.5) + 4 analog outputs (class 0.5) (8AI+4AO)
MCM
1 RS485/Modbus-RTU, support master mode or slave mode
MCP
1 Profibus-DP, Configure this function to give MCM function, referred to as MCMP for short.
MCE
1 Ethernet, support Modbus-TCP, http, SMTP, DHCP protocol,Configure this function to give MCM function, referred to as: MCME

MTH
4 ways of temperature measurement, 1 way of temperature and humidity control
Note:When selecting the extended function, the meter can take up to 3 modules. The modules can be the same or different, but MCP\MCE\MLOG cannot select multiple identical modules combined, MCP and MCE only Can choose one. The installation sequence can be arbitrary. If Ethernet or Profibus function is recommended for installation, it is recommended to install it near the A of the main body. For the location of A, please refer to 3.3 Assembly.
Technical Parameters
1. Technical Parameters of APM800, APM801 and APM8100
Technical Parameters
Index






Signal
Electrical network
Three-phase three-wire, three-phase four-wire, see the wiring diagram;
Frequency
45~65Hz;


Voltage
Rated value:AC 100V、110V、400V、690V;
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second;
Power consumption: < 0.5VA (per channel);


Current
Rated value: AC 1A, 5A, support 4 mm2 line access;
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second;
Power consumption: < 0.5VA (per channel);




Measurement accuracy
Voltage、current and power

class 0.5s/class 0.2s (APM800、APM810/APM801)
Active power
class 0.5s/class 0.2s (APM800、APM810/APM801)
Reactive power
class 2
Harmonic
1%(2rd~42nd)、2%(43rd~63rd)
Switch inputs
Dry contact inputs, built-in power supply;
Relay outputs
Contact type: open contact in main part, changeover contact in module;
Contact capacity:AC 250V/3A DC 30V/3A;
Pulse output of energy
Output mode: Optocoupler pulse with open collector;
Pulse constant:4000(5A)、8000(1A) imp/kWh;
Analog outputs
DC 0mA~20mA、4mA~20mA、0V~5V、1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω;
Analog inputs
DC 0mA~20mA、4mA~20mA、0V~5V、1V~5V iutput, accuracy class 0.5%
Storage card
Standard Capacity:4G,TF Card Up to 32G Capacity;

Communication
RS485 interface/Modbus-RTU protocol and DLT645 protocol
Profibus-DP interface/Profibus-DP protocol;
RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols;
Power supply
Working range: AC/DC 85V~265V or AC/DC 115~415V(P2);
Power consumption: Power consumption of the main part ≤ 15VA;







Safety





Power frequency withstand voltage
The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC
4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC
2kV/1min;
The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output
is AC 1kV/1min;
Insulation resistance
Inputs、outputs to the shell>100MΩ;
Electromagnetic compatibility
Meet IEC 61000 standard (Level 4);

Environment
Operating temperature: -20 °C ~ +65 °C;
Storage temperature: -20°C~+70°C;
Relative humidity: ≤95% without condensation;
Altitude: ≤2500m;






Standards
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
Environmental Testing-Part 2-1:Tests Test A:Cold IDA
Part 2-1:Tests Test B:Dry heat
Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h)
IEC 61000-4
Electromagnetic compatibility-Testing and measurement techniques


IEC 61557-12
Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c –Equipment for testing,measuring or monitoring
of protective measures- Part12:
Performances measuring and monitoring devices(PMD)

IEC 62053-22
Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s)
2. Technical Parameters of APM830
Technical Parameters
Index


Display
Display method
Dot matrix LCD
Resolution
192 * 160
Backlight
White LED
Visible area
69mm*62mm(2.8Inch / 6.66inch)






Signal
Electrical network
Three-phase three-wire, three-phase four-wire, see the wiring diagram;
Frequency
45~65Hz;


Voltage
Rated value:AC 3*57.7/100V、AC 3*63.5/110V、AC 3*230/400V、AC 3*400/690V;690V direct connection on voltage input terminal(L-L)
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second;
Power consumption: < 0.5VA (per channel);


Current
Rated value:AC 3x 1 (1.2) A、AC 3x5(6)A, support 4 mm2 line access;
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second;
Power consumption: < 0.5VA (per channel);








Measurement accuracy
Voltage、current
IEC 61557-12 class 0.2
Voltage imbalance
IEC 61557-12 class 0.2
Voltage harmonics, current harmonics


IEC 61557-12 class 2 (Note1)

frequency
IEC 61557-12      class 0.2s
Active power
IEC 61557-12 class 0.2s
Reactive power
IEC 61557-12 class 1s
inspecting power
IEC 61557-12 class 0.2
Active energy
IEC 62053-22 - Active energy 0.2S
Reactive energy
IEC 62053-24 - Reactive energy 0.5S



Power Quality
Recording wave
20 waveforms, 10 waves before and after;
Waveform capture
Each waveform is stored at 128 cycle points; the TF card is supported to expand the recorded data, and the customer needs to
manually pull the line chart through Excel.
Switch inputs
Dry contact inputs, built-in power supply;
Response time: less than 300ms

Relay outputs
Contact type: open contact in main part, changeover contact in module;
Contact capacity:AC 250V/3A DC 30V/3A;

Pulse output of energy
Output mode: Optocoupler pulse with open collector;
Pulse constant:10000imp/kWh(default),For details, see 6.2 Input Settings.;

Analog outputs
DC 0~20mA、4~20mA、0~5V、1~5V Output, accuracy grade 0.5%, load resistance ≤500Ω at current output, load resistance ≥2KΩ at voltage
output; overload: 1.2 times rated value (continuous);

Analog inputs
DC 0~20mA, 4~20mA, 0~5V, 1~5V input, accuracy grade 0.5; overload: 1.2 times rated value (continuous);
TF Storage card
Standard TF card with 4G capacity, maximum support for TF card with 32G capacity;

Communication
RS485 interface/Modbus-RTU protocol and DLT645 protocol
Profibus-DP interface/Profibus-DP protocol;
RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols;

Power supply
Working range: AC/DC 85V~265V or AC/DC 115~415V(P2);
Power consumption: Power consumption of the main part ≤ 15VA;








Safety





Power frequency withstand voltage
The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC
4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC
2kV/1min;
The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output
is AC 1kV/1min;
Insulation resistance
Inputs、outputs to the shell>100MΩ;
Electromagnetic compatibility
Meet IEC 61000 standard (Level 4);

Environment
Operating temperature:-25℃~+70℃;
Storage temperature:-40℃~+85℃;
Relative humidity:≤75% without condensation;
Altitude:≤2000m;

Protection Level
Display panel IP54, with gasket;










Standards
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
Environmental Testing-Part 2-1:Tests Test A:Cold IDA
Environmental Testing Part 2-2:Tests Test B:Dry heat
Environmental Testing Part 2-30:Tests Test Db:Damp heat,cyclic (12+12h)

IEC 61000-4
Electromagnetic compatibility-Testing and measurement techniques


IEC 61557-12
Electrical safety in low voltage distribution systems up to 1 000V a.c. and 1 500V d.c –Equipment for testing, measuring or
monitoring of protective measures — Part12:Performances measuring and monitoring devices(PMD)


IEC 62053-22
Electricity metering equipment (a.c.)-Particular requirements - Part 22: Static meter for active energy(class 0.2S and 0.5S)

IEC 62053-24
Electricity metering equipment (a.c.)-Particular requirements - Part24:Static meter for reactive energy at fundamental frequency
(classes 0.5S 1S and 1)
Dimension
Wiring
Installation
Typical Connection