Categories

Manufacturer 450VA Toroidal Transformer , Single Phase Transformer .

category: Transformers

reference price:¥$21.23 - $23.23

Purchase quantity
- +

Yueqing Yomin Electric Co., Ltd

Ms. Li
Product details Company introduction
Parameter information

450VA Toroidal Transformer      Model: DH-450

Product Overview

Selection of Toroidal Transformer

Toroidal Transformers offer many advantages over standard laminated power

 

transformers. Toroidals provide quiet, efficient operation with very low stray magnetic

 

fields. Their small size and weight support a package that is easy to design into any

 

application.

 

Advantages of Toroidal Transformer

1.     A toroidal transformer weighs about half as much as conventional transformer with the same capacity and heat rise. The main materials used in transformer are copper and steel, both of which are getting scarcer with cost increases as a consequence.

 

2.     No impregnation is needed to keep the laminates quiet so this potential environmental hazard is avoided.

 

3.     The toroidal transformer fits into a smaller space, which allows chassis plates and enclosures to be smaller with less material used.

 

How to find VA for Transformers

Volt amps (VA) is the effective power rating for a transformer. In the perfect transformer, the voltage and current (combined) applied at the primary will exactly equal the voltage and current (combined) on the secondary(s).

 

Efficiency is measure of a transformer’s ability to delivery the input power to the load. Efficiency is expressed as a percent by:

 

% = ( PO / PI ) X 100             (Where: PO = Output power, PI = Input power, % = Efficiency)

 

VA Calculation

1.     Read the transformer’s secondary winding rating (printed or tagged on the transformer case). This should give a rating such as 5V, 500mA.

Multiply the voltage times the current to receive the VA.

Example: 5V times 500mA (or 0.5A) equals 2.5VA

 

2.     Convert the secondary winding VA value to the primary winding VA rating as the equation VA (Primary) equals VA (Secondary) or VA (p) = VA(s)

For example of a 2.5VA secondary, if the primary voltage is 120V the current will be A (p) = VA(s) / V(p). Giving A(p) = 2.5 / 120 = 0.020833 (roughly 21mA).

This is the calculation for a single input winding/single output winding transformer.

 

3.     Add the separate VA ratings for a transformer with multiple secondary windings.

For secondary winding 1 = 5VA at 500mA

Secondary winding 2 = 24V at 100mA

Total Secondary VA = ( 5 X 0.5 ) + ( 24 X 0.1 ) = 4.9VA

Primary VA will still equal the total secondary VA.

Specifications

 

  • Capacity..............................................................................450VA
  • Frequency...........................................................................50/60Hz
  • Max. Temperature..............................................................60℃
  • Temperature Class............................................................Class B (130℃)
  • Voltage Combination........................................................Pls. see selection form.
  • Winding Material................................................................100% Copper
  • Mounting Metal Disk.........................................................Provided
  • Rubber Gasket...................................................................Provided
  • Standards........................................VDE0550, IEC204-1, IEC61588, EC439
  • Sample Service..................................................................Pay to Provide
  • Quality Assurance.............................................................24 months
  • Item Condition....................................................................Brand-New
Selection Form
ItemCapacityStatic CurrentEfficiencyVoltage Combination

Case

Qty.

Model(VA)(mA)(%)Primary (V)/Secondary (V)(Pcs)
DH-50501090230/24;220/24;230/36; 220/36;440/230;230/12; 130-240/15-240;115/2424
DH-100100159224
DH-150150209324
DH-200200309424
DH-250250359418
DH-300300409418
DH-350350459518
DH-400400509518
DH-450450559518
DH-500500559518
DH-550550559518
DH-600600559518
DH-700700609512
DH-800800659512
DH-10001000759512

Note: 

Please mention the voltage Combination when ordering. Other else multiple volage combination upon request.

Dimension

 

 

 NB: For Custom design, please contact our sales team.

Company Information