Categories

ST2307 ground resistance tester using a combination of 2-pole and 3-pole stakes and a clamp

category: Resistance Meters

Purchase quantity
- +

Starmeter Instruments Co., Ltd.

Ms. Tang
Product details Company introduction
Parameter information

ST2307 ground resistance tester using a combination of 2-pole and 3-pole stakes and a clamp

 

The ST2307 is distinctive earth ground tester that can perform all four types of earth ground measurement. Specifically, the ST2307 is able to measure earth ground loop resistances using only clamps – called Stakeless testing. This method doesn’t require the use of earth ground stakes or the disconnection of ground rods.

Testing Methods

2 Pole and 3 Pole Fall of Potential – standard earth ground testing using two grounds stakes

Selective testing – without disconnecting ground rods, a technician can measure ground resistance using a combination of stakes and a clamp.

Stakeless testing – innovative solution using only clamps, instead of ground stakes, to measure earth ground loop resistance.

The ST2307 offers these advanced features

Automatic Frequency Control (AFC) – identifies existing interference and chooses a measurement frequency to minimize its effect, providing a more accurate earth ground value.

R* measurement – calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to-earth ground would see.

Adjustable limits – for quick test result verification.

One-button measurement concept

2- pole and 3-pole earth ground measurement and soil resistivity testing

Selective testing, no disconnection of ground conductor (1 clamp)

Stakeless testing, quick ground loop testing (2 clamps)

Measuring AC current to 20A

Continuity with buzzer

99 memory locations and PC Software for print-out of measurement report.

Specifications

 

Specifications

Range

Resistance

Accuracy

Earthing-resistance test

(2-Pole & 3-pole)

0.01 ~ 19.99 Ω

0.01Ω

±(2% + 3)

20.0 ~ 199.9 Ω

0.1Ω

200 ~  999 Ω

1.000 ~ 1.999 KΩ

0.001KΩ

2.00 ~ 19.99 KΩ

0.01KΩ

Earthing-resistance test

(2-Pole clamps & 3-pole clamps)

0.02~19.9Ω

0.01Ω

±(5% + 5)

20 ~ 150Ω

0.1Ω

±(10% + 5)

Soil resistance ρ

0.06 ~ 99.99 Ω.m

0.01Ωm

±(2% + 3)

100.0 ~ 999.9 Ω.m

0.1Ωm

1.000 ~ 9.999 KΩ.m

0.001 kΩ.m

10.00 ~ 99.99 kΩ.m

0.01 kΩ.m

100.0 ~ 999.9 kΩ.m

0.1 kΩ.m

1000 ~ 1999 kΩ.m

1 kΩ.m

AC current

0.1mA ~ 0A

0.1mA

±(2% + 3)

Disturbance voltage (Ust)

50.0 V

0.1v

±(2% + 2)

Disturbance frequency (Fst)

16Hz – 500 Hz

0.1Hz

±(1% + 0.5Hz)

Frequency

128Hz  / 111Hz  / 105Hz  / 94Hz  / AFC

Voltage

0.1-50V(0.1V)

Short-circuit current

<20mA

Features

2-Pole, 3-pole

ρ measurement

Buzzer

Display Backlight

Interference Vol / Fre

RK (Wire Compensation)

Automatic compensation

Safety Rating

CAT III 300V

Applicable standards

EN61010-1, EN61557-1-5,EN61187,EN61010-031

Data storage

99 Groups

USB 2.0

General

Display

FSTN LCD; 102×86.6 mm

Power

8x1.5V R14SG SIZEC Type

Dimension

270(W)×190(L)×80(D)mm

Weight

Approx. 4.0 kg

 

 

Accessories

 Simplified measurement test leads (Blue:30M,Red: 15M, Black:6M, Green:6M)

Auxiliary earth spikes (2 spiks/set)×2 sets (4 spikes in total)

Cord reel [4 pcs])×1 set

USB adaptor with (Software)

Shoulder strap

Carrying case

R14SG*8 Battery

Instruction manual

AC Current-clamp 2 Set (1000/1A)