Categories

Fluke 772 Milliamp Process Clamp Meter

category: Clamp Meters

reference price:¥$1,299.99 - $1,999.99

Purchase quantity
- +

Shenzhen Yearstar Intelligent Technology Co., Limited

Ms. Jiang
Product details Company introduction
Parameter information
Product Description

   Fluke 772 Milliamp Process Clamp Meter 

  • Digital clamp-meter for 24V loop circuits measures direct current (DC) to 100mA via clamp and to 24mA in circuit
  • Meter can source and simulate DC signals from 4 to 20mA, and is accurate to 0.2% with a resolution of 0.01mA
  • Clamp with 4.5mm (0.177 inches) jaw opening measures current without touching or interrupting the circuit, and is for use in hard-to-reach applications
  • Built-in 24V-loop power supply to power a transmitter and measure its milliampere output signal
  • Meets EN and IEC safety standards 61010-1 and 61010-2-032
Diameter of measurable conductor0.177” or 4.5 mm max
Operating temperature-10 to 50 ºC
Storage Temperature-25 to 60ºC
Operating Humidity< 90% @ <30 ºC, < 75% @ 30 to 55ºC
Operating Altitude0 to 2000 m
IP RatingIP 40
Size59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.)
Weight260G, (9.1 oz.)
VibrationRandom 2 g, 5 to 500 Hz
Shock1 meter drop test (except the jaw)
EMI/RFIMeets EN61326-1 
Note: For current measurement w/ JAW, add 1mA to 
specification for EMC field strengths of 1V/m up to 3V/m.
Temperature Coefficient0.01% ºC 
(<18? or > 28?)
Power, battery life(2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical
WarrantyThree years for electronics one year for cable and clamp assembly

 

Functional Specifications

mA measurement 
(Measured by clamp) 
Resolution and Range:     0 to 20.99 mA
Accuracy:                        0.2% + 2 counts
Resolution and Range:     21.0mA to 100.0 mA
Accuracy:                        1% + 5 counts
mA measurement 
(Measured in series with test jacks) 
Resolution and Range:
Resolution and Range:     0 to 24.00 mA
Accuracy:                        0.2% + 2 counts
mA source (Maximum mA Drive: 
24 mA into 1,000 ohms) 
Resolution and Range:
Resolution and Range:     0 to 24.00 mA
Accuracy:                   0.2% + 2 counts
mA simulate 
(Maximum voltage 50 V dc) 
Resolution and Range:
Resolution and Range:     0 to 24.00 mA
Accuracy:                   0.2% + 2 counts

 

 
 

Product Description

Fluke 772 Milliamp Process Clamp On Meter with Integrated mA Loop can measure mA signals without breaking the loop. The Fluke 772 mA Clamp Meter expand upon the capabilities of the popular 771 mA Clamp Meter, adding loop power and mA sourcing to the troubleshooting and process calibration capabilities in all Fluke mA clamp meters. If you are spending time taking mA measurements by removing a wire and breaking the loop, calling the control room to isolate a loop, testing analog input/output on a console, troubleshooting devices with mA inputs and outputs, repairing intermittent or erratic 420 mA loops, going back to the shop to get extra tools then you need to take a good look at the Fluke 772 mA Clamp Meters. It's designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 420 mA loops without breaking the loop or bringing down the system.Fluke Meter includes: Four AA alkaline batteries (installed), Soft carrying case, TL75 test leads, AC 72 detachable clip, TL 940 mini hook test leads, Instruction sheet, Hanging tool with hook and loop strap.

contact me