non contact voltage test digital multimeter FLUKE 117

category: Multimeters

reference price:¥$8,888.00 - $9,999.00

Purchase quantity
- +

Shenzhen Yearstar Intelligent Technology Co., Limited

Ms. Jiang
Product details Company introduction
Parameter information

VoltAlert™ technology for non-contact voltage detection

  • AutoVolt automatic AC/DC voltage selection
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • True RMS for accurate measurements on non-linear loads
  • Measures 10 A (20 A overload for 30-seconds)
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
  • CAT III 600 V safety rated

 

 

Specifications

Maximum voltage between any terminal and earth ground

 

 600 V

 

Surge protection

 

 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2

 

Fuse for A input

 

 11 A, 1000 V FAST Fuse (Fluke PN 803293)

 

Display

Digital:

 6,000 counts, updates 4 per second

 

Bar graph

 

 33 segments, updates 32 per second

 

Operating Temperature

 

 -10 °C to + 50 °C

 

Storage Temperature

 

 -40 °C to + 60 °C

 

Battery type

 

 9 volt Alkaline, NEDA 1604A/ IEC 6LR61

 

Battery Life

 

 400 hours typical, without backlight

 

 

Accuracy Specifications

DC millivolts

Range/Resolution:

 600.0 mV/0.1 mV

 Accuracy: ± (0.5% + 2)

 

DC volts

Range/Resolution:

 6.000 V / 0.001 V

 Accuracy: ± (0.5% + 2)

 60.00 V / 0.01 V

 600.00 V / 0.1 V

 

Auto volts

Range/Resolution:

 600.0 V/0.1 V

 ±(2.0 % + 3) (dc, 45 Hz to 500 Hz)
 ±(4.0 % + 3) (500 Hz to 1 kHz)

 

 

AC millivolts1 true-rms

Range/Resolution:

 600.0 mV/0.1m V

 ±(1.0 % + 3) (dc, 45 Hz to 500 Hz)
 ±(2.0 % + 3) (500 Hz to 1 kHz)

 

AC volts1 true-rms

Range/Resolution:

 6.000 V / 0.001 V

 ±(1.0 % + 3) (dc, 45 Hz to 500 Hz)

 60.00 V / 0.01 V

±(2.0 % + 3) (500 Hz to 1 kHz)

 600.0 V / 0.1 V

 

Continuity

Range/Resolution:

 600 Ω/1 Ω

Beeper on < 20 Ω,off > 250 Ω ; detects opens or shorts of 500 μs or longer.

 

Ohms

Range/Resolution:

 600.0Ω/0.1 Ω

 Accuracy: ±(0.9 % + 2)

 6.000 kΩ/0.001 kΩ

 Accuracy: ±(0.9 % + 1)

 60.00 kΩ/0.01 kΩ

 600.0 kΩ/0.1 kΩ

 6.000 MΩ/0.001 MΩ

 40.00 MΩ/0.01 MΩ

 Accuracy: ±(1.5 % + 2)

 

Diode Test

Range/Resolution:

 2.000 V / 0.001 V

 Accuracy: ±(0.9 % + 2)

 

Capacitance

Range/Resolution:

 1000 nF / 1 nF

 Accuracy: ±(1.9 % + 2)

 10.00 μF / 0.01 μF

 100.0 μF / 0.1 μF

 9999 μF / 1 μF

--

 100 μF to 1000 μF

 Accuracy: ±(0.9 % + 2)

 > 1000 μF

 Accuracy: ±(5 % + 20)

 

LoZ capacitance

Range:

 1 nF to 500 μF

 Accuracy: ±(10 % + 2) typical

 

AC amps true-rms (45 Hz to 500 Hz)

Range/Resolution:

 6.000 A / 0.001 A

 Accuracy: ±(1.5 % + 3)

 10.00 A / 0.01 A

 20 A continuous overload for 30 seconds max

 

DC amps

Range/Resolution:

 6.000 A / 0.001 A

Accuracy: ±(1.0 % + 3)

 10.00 A / 0.01 A

 20 A continuous overload for 30 seconds max

 

Hz (V or A input)2

Range/Resolution:

 99.99 Hz / 0.01 Hz

 Accuracy: ±(0.1 % + 2)

Range/Resolution:

 999.99 Hz / 0.1 Hz

Range/Resolution:

 9.999 kHz / 0.001kHz

Range/Resolution:

 50.00 kHz / 0.01 kHz

 

 

 