Categories

medical intelligent insulation monitoring instrument AIM-M100

category: Resistance Meters

Purchase quantity
- +

Acrel Electric Co., Ltd.

Ms. Fan
Product details Company introduction
Parameter information

General

AIM-M100 medical intelligent insulation monitoring instrument adopts advanced microcontroller technology, which has high integration, compact size, convenient installation and integrates intelligence, digitalization and networking in one. It is ideal selection for insulation monitoring of isolation power system in Class 2 medical.

 

Product Functions

Ø Functions of real-time monitoring and fault alarming of the ground insulation resistance, transformer load current and transformer winding temperature of the monitored IT system;

Ø Can be used with insulation fault locator, remotely starting fault-locating and displaying locating results when there are insulation faults;

Ø Real-time monitor the line disconnection fault, temperature sensor disconnection fault and the functional grounding line disconnection fault of the monitored system, and give the alarm indication when the fault occurs;

Ø Relay alarm output, LED alarm indication and other faults indication functions;

Ø Two kinds of fieldbus communication technology, which are used for centralized alarm and display instrument, test signal generator, insulation fault locator and upper computer management software communications, and can monitor the operation status of IT system in real time.

Ø Events logging function, which can record alarm occurrence time and fault type and is convenient for operation personnel to analyze the operation conditions of system and promptly eliminate the faults;

 

 Technical Parameter

Technical parameters of AIM-M100 insulation monitoring instrument

Auxiliary power supply 

Voltage

AC220V

(fluctuating range±10%)

Temperature measurement

Thermistor

PT100

Frequency

50/60Hz

Measuring range

-50—+200

Maximum power consumption

<8W

Alarm value scope

0—+200 

Insulation monitoring

Measuring range of insulation resistance

10-999kΩ

Alarm output

Output mode

2-route relay output(programmable) 

Absolute percentage error

0—±10%

Contact capacity

AC 250V/3A  DC 30V/3A

Alarm value scope

50—999kΩ

Environment

Operating temperature

-10—+55 

Response time

<2s

Storage temperature

-20—+70

Measuring voltage

<12V

Relative humidity

5%-95%, non-condensate

Measuring current

<50uA

Altitude

≤2500m

 

Load current

Measuring range

2.1-50A

Communication

RS485 interface, Modbus-RTU

agreement

Alarm value scope

5-50A

Rated impulse voltage/pollution degree

4KV/

 

Measuring accuracy

≤±5%

EMC electromagnetic compatibility/electromagnetic radiation

Conform to IEC 61326-2-4

Wiring

Dimension drawings

 

Product selection

Type

Picture

Description

AITR series medical isolation transformer

 

AITR series isolation transformer is specially used in medical IT system. The windings are treated with double insulation and have electrostatic shielding layer, which reduces electromagnetic interference between windings. The PT100 temperature sensor is installed in the wire bag to monitor the temperature of transformer. The whole body is treated with vacuum invasion paint, which increases mechanical strength and corrosion resistance. The product has good temperature rise performance and very low noise.

AIM-M100 medical intelligent insulation monitoring instrument

The AIM-M100 medical intelligent insulation monitor is compact in size, easy to install, intelligent, digital and networked, and is an ideal choice for insulation monitoring of isolation power supply systems in operating rooms, intensive care units and other medical places.

AKH-0.66P26 current transformer

 

The AKH-0.66P26 type current transformer is the protective current transformer supporting the AIM-M100 insulation monitor, of which the maximum measurable current is 60A and the transformation ratio is 2000:1. The current transformer is directly fixed inside cabinet by screwing, and the secondary side is leaded out by the terminal, which is convenient to install and use.

ACLP10-24 dc power module

 

Special DC module for instrument, stable output voltage. The module adopts the standard guide way to install, and can be installed on the same guide way with the insulation monitor, easy to install.

AID series external alarm and display instrument

 

AID120

 

It is suitable for wall installation embedded in operating room or nurse station and can monitor 1 AIM-M100 insulation monitor. It has sound and light alarm function of insulation, overload, overtemperature and equipment failure, digital tube display and RS485 communication

AID150

 

LCD display, RS485 bus, centralized monitoring of up to 16 SETS of AIM-M100 medical intelligent insulation monitor data, sound and light alarm can be remote. The AID150 can also monitor data from multiple AIM-R100 residual current monitors.