AOYI High Precision New Design SCR Voltage Regulator/Stabilizer ZK7-12

Purchase quantity
- +

Shanghai Aoyi Electric Co., Ltd.

Ms. Z
Product details Company introduction
Parameter information
Advantages

High precision,strong earthquake resistance,good reliability,strong anti-interference,clear reading and so on.

Widely applicable to the temperature adjustment of mechanical equipment such as plastic suction machine.

Overview

1.ZK7-12 channel voltage regulator is a new type of combined voltage regulator,which takes single-chip microcomputer as the core and changes the value on the load by means of phase-shifting trigger.The voltage regulator can continuously adjust the voltage on the load.As the voltage regulator adopts deep voltage negative feedback,this group of regulators has excellent voltage stability and good linear of adjustment.

2.The voltage regulator can be connected with single-phase or three-phase,and the load must be in a common zero line in three-phase.Voltage regulator has 12 channels of output.When used in three phase,phase A,phase B,phase C are corresponding to four channels,each channel can be connected to a load,directly adjust the resistance load on the voltage to achieve temperature control,such as heating watts.

3.Each voltage regulator can be used independently or in combination to form a system directly connected to the touch screen.The voltage regulator adopts the RS485 bus interface and the general Modbus-RTU communication protocol to make the wiring more convenient and simple and the touch screen call more convenient.

4.The setting and control of the voltage regulator are all controlled by the upper computer.One set of setting parameters is power loss memory.Single channel control on or off,but also a key control of all channels on or off,convenient and efficient.

Product Details

▲Main Technical Indicators

1.Power line input: single-phase(AC220V±10%) or three-phase four-wire(AC380V±10%) input,50/60HZ universal,(the machine consumes power less than 4W,the total power depends on the load power);

2.Output voltage:AC0-220V(mean value),single channel output maximum power(resistance load,good ventilation and heat dissipation conditions):-06 maximum 650W,-15 maximum 1500W;

3.Working environment:temperature 0-50℃,relative humidity of not more than 85% without corrosive occasions;

4.Maximum phase-shifting voltage regulation conduction angle: not less than 170 ̊;

5.Communication: RS485 two-wire bus,MODBUS-RTU protocol. 

▲Model Name and Installation

ZK7-12-□

ZK: Voltage regulator series

7: Phase-shifting voltage regulation type

12: Combined voltage regulator series: "12" means 12 channels

:Integrated voltage regulator,single circuit can directly drive resistance load power:

"650" means 650W, "1500" means 1500W.

Communication

1. Setting of communication address: Adopt two-bit BCD dialing switch to realize the setting of the address range from 1 to 99(turn off the communication function when set to 0).

2. Function code:

3. Address table: The register address arrangement of this controller is exactly the same as the register address of ZK7-12 discrete voltage regulator.The address is as follows:


4. Function code "02" can be used to read the input logical state bit address

5. Function code "01,05,0F" can be used to read and write logical state bit address

6. For the convenient of user programming,the register address arrangement of the controller integrates the read-only and read-write register addresses to make programming more flexible and convenient.The uniform address is as follows:

7. Communication Parameter

Instructions

1.Control of three phase four wire connection,such as the appended drawings, "phase A", "phase B", "phase C" respectively connected to the three-phase electric wire, "N line" connect zero live, "phase A output", "phase B output", "phase C output" are total 12 channels,then directly connect 12 loads( such as fever brick),the other end of the load connect zero line in parallel,( the load power must not exceed the rated value of the product,otherwise please contact our related technician);

2.For single-phase control,connect the "phase A", "phase B" and "phase C" in the attached drawing and directly connect them with the L(fire) line and "N line" to the zero line.The other lines shall be connected in the same way as the three-phase control;

3.The communication line "A" is connected to D+, "B" is connected to D-, "GND" is connected to the shielding layer.Then set the dialing switch to the same number as the station number set by the upper computer program;


4.Attached drawings of sample wiring for details: