Welcome to wziep.com!
Welcome to wziep.com!
category: Resistance Meters
Specification |
|||
Function |
4-pole, 3-pole ,2-pole, selection, double clamp method measure grounding resistance, Soil Resistivity; Earth Voltage, AC Voltage, AC Leakage Current |
||
Parameters |
Range |
Accuracy |
Resolution |
Selection Method (0.00Ω-3000Ω) |
0.00Ω-30.00Ω |
±2%rdg±3dgt |
0.01Ω |
30.00Ω-300.0Ω |
0.1Ω |
||
300Ω-3000Ω |
1Ω |
||
Double Clamp Method (0.00Ω-9000kΩ) |
0.01Ω-1.00Ω |
±10%rdg±5dgt |
0.1Ω |
1.0Ω-10.0Ω |
0.01Ω |
||
10Ω-100Ω |
1Ω |
||
2/3/4 Pole Method (0.00Ω~30.00kΩ) |
0.00Ω~30.00Ω |
±2%rdg±3dgt |
0.01Ω |
30.0Ω~300.0Ω |
0.1Ω |
||
300Ω~3000Ω |
1Ω |
||
3.00kΩ~30.00kΩ |
±4%rdg±3dgt |
10Ω |
|
Soil Resistivity (0.00Ω~9000kΩ) |
0.00Ωm~99.99Ωm |
According to the precision of R (ρ=2πaR a:1 m-100m, π=3.14)
|
0.01Ωm |
100.0Ωm~999.9Ωm |
0.1Ωm |
||
1000Ωm~9999Ωm |
1Ωm |
||
10.00kΩm~99.99kΩm |
10Ωm |
||
100.0kΩm~999.9kΩm |
100Ωm |
||
1000kΩm~9000kΩm |
1kΩm |
||
Earth Voltage |
0.0V~100.0V |
±2%rdg±3dgt |
0.1V |
AC Current |
0.00mA~600A |
±2%rdg±3dgt |
0.01mA |
Measuring Mode |
Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement, selection method, double clamp method |
||
Measuring Method |
2/3/4 pole method: change-pole method, measurement current 20mA Max Selection method: change-pole method, measurement current 20mA Max Double clamp method: disconnect mutual inductance method, measurement current 1mA Max Soil Resistivity: 4-pole measurement (Wenner method) Earth Voltage: average rectification(between P(S)-ES) AC current: mutual inductance method |
||
Test Frequency |
128Hz/111Hz/105Hz/94Hz(AFC) |
||
Short-circuit Test Current |
AC 20mA max |
||
Open-circuit Test Current |
AC 40V max |
||
Test Voltage Wave |
Sine wave |
||
Electrode Distance Range |
1m-100m |
||
Features |
|||
Operation Way |
Auto Range |
||
Backlight |
√ |
||
Display |
4-digital large LCD ,124mmx67mm |
||
Clamp Size |
Φ68mm |
||
Measuring Indicator |
LED flash / LCD countdown / analog bar |
||
Sampling Rate |
Voltage to ground: 2 times/s |
||
Current to ground: 2 times/s |
|||
Earth resistance, soil resistivity: 5 seconds/time |
|||
Measuring Times |
Over 5000 times (Short-circuit test, interval time should be at least 30 seconds) |
||
Interface |
RS232 |
||
Data Storage |
2000 groups |
||
Data Hold |
√ |
||
Over range indication |
“OL” display |
||
Interference Test |
Automatically, interference voltage > 5V : “NOISE” display |
||
Auxiliary Earth Test |
Can measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ) |
||
Alarm |
√ |
||
Low Battery Indication |
√ |
||
Auto Off |
15minutes idle |
||
Working Condition |
-10℃-40℃, < 80%RH |
||
Storage Condition |
-20℃-60℃, <70%RH |
||
Insulation |
Over 20MΩ (between circuit and enclosure it is 500V) |
||
Withstanding Voltage |
AC 3700V/rms. (Between circuit and enclosure) |
||
Electromagnetic Features |
IEC61326(EMC) |
||
Safety |
IEC61010-1 (CAT Ⅲ 300V,CAT IV 150V,Pollution 2), IEC61010-031, IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004 |
||
General Information |
|||
Power Supply |
R14S 1.5V 6 PCS |
||
Product Size |
215mm×190mm×95mm |
||
Product Weight |
Total weight: 8.0kg (including package) Tester: 1653g (including battery) Testing wires: 1560g Auxiliary earth rods: 935g (4pcs) |
||
Standard Accessories |
Clamp x2pcs , Manual x 1pc , Test Wires (red 20m, black 20m, yellow 10m, green 10m) ,Short Test leads (red 1.6m , black 1.6m) , Earth Rod (Φ10mm×150mm)x4pcs , RS232 Cable + Software CD x 1pc , Tool Case x 1pc |