Acrel ASJ10-LD1A Protection Rail Mounting Earth Leakage Relay Electromagnetic RELAY PROTECTIVE Epoxy

category: Relays

Purchase quantity
- +

Jiangsu Acrel Electrical Manufacturing Co., Ltd.

Ms. Li
Product details Company introduction
Parameter information

ASJ10-LD1C

* Measurement of AC-type after-current;
* Indicator of current off-limit alarm; The setting of rated residual action current ( see in the table 2);
* The setting of non-driving time of limitation ( see in the table 2);
* Two-pair relay output;
* Possessing the function of on-the-spot and long-distance testing and resetting;

ASJ10-LD1A

* The measurement of A-type after-current;
* The streamer display of current percentage;
* The setting of rated residual action current ( see in the table 2);
* The setting of non-driving time of limitation ( see in the table 2);
* Two- pair relay output(both of which can be set) *;
* Possessing the function of on-the-spot and long-distance testing and resetting
Technical Parameter
technical parameter


ASJ10-LD1C
ASJ10-LD1A
Input
Rated residual action current I△n

0.03、0.1、0.3、0.5(A)
0.03、0.05、0.1、0.3、0.5、1、3、5、10、
30(A)

Non-driving time of limitation △t

0.1、0.5(s)

0、0.06、0.1、0.2、0.3、0.5、0.8、1、4、
10(s
Rated residual non-action current I△no
50%I△n
50%I△n
performance characteristics
simple sinusoidal alternating current
simple sinusoidal alternating current and pulsating direct current
frequency
50Hz/60Hz
50Hz/60Hz
action error
-20% ~ -10%I△n

output
output mode

one is the normal closing and the other is for the transformation
one is the normal closing or opening, and the other is for the transformation

contact capacity

5A 250VAC 5A
30VDC
AL1:8A 250VAC 5A 30VDC AL2:6A 250VAC 5A 30VDC

reset mode

the on-the-spot one and the long-distance one,
the on-the-spot one, the long-distance one and the automatic one
power supply
voltage range

AC110V、AC220V
(permissible error±10%)
AC110V、AC220V、DC85-270V
(permissible error±10%)

power dissipation

≤5W

power frequency withstand voltage


The effective value of alternating current between the power supply, input and output: 2kV/1min

under the normal operation

temperature
operating temperature: -20℃ ~ +55℃
storage temperature: -30℃ ~ +70℃


humidity
≤95%RH, with moisture condensation, and corrosive gas place

Altitude
≤2000m
class of pollution
Grade three
installation category
Type Ⅲ
Residual Current CT
Type
Rated Current
L-45
16-100A
L-80
100-250A
L-100
250-400A
L-150
400-800A
L-200
800-1500A
Type
Rated Current
L-80*50II
16-200A
L-100*50II
16-100A
L-130*50II
100-200A
L-150*130II
100-300A
L-180II
100-200A
L-200*50II
250-400A
L-260-100II
450-800A
Typical connection
Wiring
Application
Solution
1. Through the PLC to collect the output state of the relay, and then judge the operation state of the relay.
2. Through RS485 communication to network