earth resistance soil resistivity meter digital earth resistance tester

 

Product Description

Clamp meter series leakage current clamp meter AC clamp meter HZ3200 soil resistance tester introduction:

HZRC3200 Double Clamp Grounding Resistance Tester is specially design for the measurement of earth resistance, soil resistivity, earth voltage, leakage current of grounding line, AC current, DC resistance.

HZRC3200 Double Clamp Grounding Resistance Tester is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. At the same time it can store 2000 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, and alarm indicator, auto-shut down and with the functions like historical data access, reading, preservation, report forms, printing and so on.

 

Clamp meter series leakage current clamp meter AC clamp meter HZ3200 soil resistance tester specifications: 

Function
4-pole, 3-pole and simple 2-pole, selection, double clamp method measure grounding resistance, soil resistivity; Measurement of earth voltage, AC voltage, leakage current of AC current
Power Supply
DC 9V(Zn-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours )
Caliber of clamp
Φ68mm
Measurement Range
Selection method: 0.00Ω-3000Ω
Double clamp method: 0.00Ω-9000kΩ
2/3/4 pole method:0.00Ω~30.00kΩ
Soil resistivity:0.00Ω~9000kΩ
DC resistance:0.00Ω~30.00kΩ
Earth voltage:0.0V~100.0V
AC current:0.00mA~600A
Measuring Mode
Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement, selection method, double clamp method measure grounding resistance
Measuring Method
2/3/4 pole method: change-pole method, measurement current 20mA Max
Selection method: change-pole method, measurement current 20mA Max
Double clamp method: disconnect mutual inductance method, measurement current 1mA Max
Soil Resistivity: 4-pole measurement (Wenner method)
Earth Voltage: average rectification(between P(S)-ES)
AC current: mutual inductance method
Test Frequency
128Hz/111Hz/105Hz/94Hz(AFC)
Short-circuit Test Current
AC 20mA max
Open-circuit Test Current
AC 40V max
Test Voltage Wave
Sine wave
Electrode Distance Range
Can be set 1m-100m
Shift
automatic shift
Backlight
Blue screen backlight, suitable for dim places
Display Mode
4-digital super-large LCD display, blue screen backlight
Measuring Indicator
During measurement, LED flash indicator, LCD countdown display, progress bar indicator
LCD Frame Dimension
128mm×75mm
LCD Window Dimension
124mm×67mm
Dimension
L×W×H: 215mm×190mm×95mm
Standard Test Wire
4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
Simple Test Wire
2 wires: each for red 1.6m and black 1.6m
Auxiliary Earthing Rod
4 wires: Φ10mm×150mm Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
Measuring Rate
Voltage to ground: about 2 times/second
Current to ground: about 2 times/second
Earth resistance, soil resistivity: about 5 seconds/time
Measuring Times
Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
RS232 Interface
RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed.
Communication Wire
One piece of RS232 communication wire, with length 1.5m
Data Storage
2000 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full
Data Hold
Data hold function: “HOLD” icon display
Data Read
Data read function: “READ” icon display
Overflow Display
Exceeding measuring range overflow function: “OL” icon display
Interference Test
Recognize interference signal automatically, “NOISE” icon display when interference voltage exceed 5V
Auxiliary Earthing Test
Can measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Alarm Function
When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint
Battery Voltage
When battery voltage decreases to about 7.5V, battery voltage low icon     will display, reminding to replace battery.
Auto-shut off
Automaticlly shut down 15minutes after booting
Power Consumption
Standby: about 20mA (Backlight shut off)
Boot and with backlight: about 45mA (25mA without backlight)
Measurement: about 100mA (Backlight shut off)
Weight
Total weight: 8.0kg (including package)
Tester: 1653g (including battery)
Testing wires: 1560g
Auxiliary earthing rods: 935g (4pcs)
Working Temperature & Humidity
-10℃-40℃, below 80%rh
Storage temperature & humidity
-20℃-60℃, below 70%rh
Overload Protection
Measuring earth resistance: between each interfaces of C(H)-E,P(S)-ES,AC 280V/3 seconds
Insulation Resistance
Over 20MΩ (between circuit and enclosure it is 500V)
Withstanding Voltage
AC 3700V/rms. (Between circuit and enclosure)
Electromagnetic Features
IEC61326(EMC)
Protection Type
IEC61010-1 (CAT Ⅲ 300V,CAT IV 150V,Pollution 2), IEC61010-031, IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004         

 

 

 Intrinsic error and performance indicators under base conditions  

Function
Measurement Range
Intrinsic Error
Resolution
2/3/4 pole method measure earth resistance
(R)
0.00Ω-30.00Ω
±2%rdg±3dgt
0.01Ω
30.0Ω-300.0Ω
±2%rdg±3dgt
0.1Ω
300Ω-3000Ω
±2%rdg±3dgt
3.00kΩ-30.00kΩ
±4%rdg±3dgt
10Ω
Selection method to measure grounding resistance(R)
0.00Ω-30.00Ω
±2%rdg±3dgt
0.01Ω
30.0Ω-300.0Ω
±2%rdg±3dgt
0.1Ω
300Ω-3000Ω
±2%rdg±3dgt
Double clamp method to measure grounding resistance(R)
0.01Ω-1.00Ω
±10%rdg±5dgt
0.1Ω
1.0Ω-10.0Ω
±10%rdg±5dgt
0.01Ω
10Ω-100Ω
±10%rdg±5dgt
Soil Resistivity
(ρ)
 
0.00Ωm-99.99Ωm
According to the precision of R
(ρ=2πaR
a:1 m-100m,
π=3.14)
0.01Ωm
100.0Ωm-999.9Ωm
0.1Ωm
1000Ωm-9999Ωm
1Ωm
10.00kΩm-99.99kΩm
10Ωm
100.0kΩm-999.9kΩm
100Ωm
1000kΩm-9000kΩm
1kΩm
Earth Voltage(50Hz/60Hz)
AC 0.0-600V
±2%rdg±3dgt
0.1V
AC current(50Hz/60Hz)
0.0mA-600.0A
±2%rdg±3dgt
0.0mA
 

1.

Certifications

 

Quality Control

 

Packaging & Shipping

 

Our Services

From the date of purchase within one year instrument, is a product quality problem free repair replacement, lifetime supply of maintenance and technical services. The instrument has found anomalies or malfunctions please contact us to arrange the most convenient treatment options.

 

Company Information

HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is  founded in 2008,the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.

Our main products : Insulation Oil Tester, Cable Fault Locator, High Voltage Generator,transformer tester, relay protection tester,insulation resistance  tester,Power Quality Analyzer and so on.

Close to Tianjin port, the transportation is convenient. our customers come from More than 50 countries, like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.

What's more, gurantee 1 year,life long maintance .Products through the CE, ISO, IEC certification, quality and reliable, factory price.

Warmly welcome all partners to join us for mutual benefits cooperation.

 

 

 

 

Test

      

      Transformer oil tester                 High voltage tester                   Transformer tester              Circuit  breaker analyzer

     

Contacts