Categories

DW9L 3 Phase CT kwh Digital Active Power Meter /energy meter with rs485

category: Energy Meters

reference price:¥$68.00 - $88.00

Purchase quantity
- +

Toky Electrical Co., Ltd.

Ms. Liu
Product details Company introduction
Parameter information

Toky DW9L series 3 phase multi-function power meter:

1) To measure: Voltage, Current, Active Power, Reactive Power, Power Factor, Frequency (Hz), Kwh, 4 Quadrant Energy, etc. Total 28 electrical parameters;

2) 240*160 dot big LCD for display.

3) Two On-Off Input / Output, with remote control RS485 Modbus communicatoin and measurement function;

4) Isolation between Input and Output signal;

5) True effective value measuring;

6) Two alarm output for Voltage, Current, Power Factor, Active Power, Reactive Power;

7) Transformed analog output 4-20mA  for voltage, current, active power, reactive power, frequency, power factor;

8) With RS485 communication function (Modbus RTU protocol);

9) With power down memory function for KWH / KvarH.

 

ModelAlarm AnalogCommunicationPulse OutputON/OFF Output
DW9L-A30BNONONO YESYES
DW9L-A38BNONORS485
DW9L-RC30B2NO NO 
DW9L-RC38B2NORS485
DW9L-DC30B24-20mANO 
DW9L-DC38B24-20mARS485

 

Multifunction Power Meter Features:
1. Suit for LV/ HV voltage system
2. Compact design with all real-time measurement
3. Consist of basic unit and optional modules
4. 10 years back-up of integrated energy data
5. Large LCD, high brightness, auto-scrolling
6. High accuracy, V or I is 0.2%, kWh is class 1
7. CT and PT programmable
8. Pluggable terminals, easy to install
9. Panel size: 96 x 96mm
10. Password protect
 
Multifunction Power Meter Basic Function:
Provide one RS485 communication, measures and display real-time parameters:
1. Voltage—Ua, Ub, Uc, Uab, Ubc, Uca,
2. Current—Ia, Ib, Ic, In
3. Active power – Pa, Pb, Pc, ∑P
4. Reactive power –Qa, Qb, Qc, ∑Q
5. Power factor—PFa, PFb, PFc, ∑PF
6. Frequency
7. Active energy—kWh
8. Reactive energy– kvarh

 

 

 

 

Connection3 Phase 3 Wires, 3 Phase 4 Wires
Rated voltage valueAC 50-260V Phase Voltage / AC 50-450V Line Voltage
Voltage overloadContinuous: 1.2 times      Instantaneous: 2 times/10S
Consumption of voltage <1VA    (each phase)
Voltage imdepance ≥ 300K Ω                                                                                      
Voltage accuracy RMS measure, accuracy class 0.5
Rated current value AC 0.025A -- 5A
Current overload  Continuous: 1.2 times      Instantaneous: 10 times/10S
Consumption of current  <0.4VA    (each phase)
Current imdepance  <20mΩ 
Current accuracy RMS measure, accuracy class 0.5
Frequency45-60Hz, accuracy 0.1Hz
Power Active / Reactive / Apparent power, accuracy 0.5%F.S.
Energy  Accuracy for Active Power and Reactive Power : 1%F.S.
DisplayLCD display
Power supply rangeAC/DC 100--240V       (85--265V)
Power supply consumption≤7VA