Categories

Fluke 355 True-rms 2000A Clamp Meters

category: Multimeters

reference price:¥$1,969.99 - $2,299.99

Purchase quantity
- +

Shenzhen Yearstar Intelligent Technology Co., Limited

Ms. Jiang
Product details Company introduction
Parameter information

Fluke 355 True-rms 2000 A Clamp Meters  :

 

  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)
  • Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

 -----------------------------------------------------------

Electrical specifications :

 

Current measurement dc and ac 10 Hz to 100 Hz
Range : 40 AResolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
Range : 400 AResolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A
Range : 2000 A; 1400 ac rmsResolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
Crest Factor (50/60 Hz)
Range : 40 ACrest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range : 400 ACrest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rmsCrest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz
Range : 40 AResolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A
Range : 400 AResolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A
Range : 2000 A; 1400 ac rmsResolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range : 4 VResolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range : 40 VResolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range : 400 VResolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 600 V ac rmsResolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 1000 V dcResolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range: 4 VResolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range: 40 VResolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 VResolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rmsResolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms measurement (355 only)
Range: 400 Ω

Resolution: 0.1 Ω

Accuracy: 1.5 % + 5 digits

Range: 4 kΩResolution: 1 Ω
Accuracy: 1.5 % + 5 digits
Range: 40 kΩ

Resolution: 10 Ω

Accuracy: 1.5 % + 5 digits

Range: 400 kΩResolution: 100 Ω
Accuracy: 1.5 % + 5 digits
Continuity beeper (355 only)
 On at ≤ 30 Ω
 Off at ≥ 100 Ω
Frequency measurement
Measurement range5.0 Hz to 1 kHz
Resolution0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz0.5 % + 5 counts
Trigger levelRefer to current and voltage tables

 

 

General specifications :

Batteries
 Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)
 100 hours
Test leads
 Rated to 1000 V
Weight
 .814 kg (1.8 lb)
Jaw size
 58 mm (2.28 in)
Dimensions (LxWxD)
 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating
 IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

 

Environmental specifications:
Operating temperature
 32 °F to + 122 °F (0 °C to +50 °C)
Storage temperature
 -4 °F to 140 °F (-20 °C to +60 °C)
Operating humidity
 0 to 95 % (non-condensing)
Operating altitude
 2000 m
Storage altitude
 10,000 m
IP rating
 42 (indoor use only)
Drop test requirements
 1 m
EMI, RFI, EMC
 FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature coefficients
Current:0.1 % of reading per °C outside 22 °C to 24 °C
Voltage:0.1 % of reading per °C outside 22 °C to 24 °C

 

 

 

 

Including accessories:

 

 

  • 355 clamp meter
  • C43 Soft carrying case
  • 6 AA batteries
  • TL224 1.5 m silicone rubber test leads
  • TP2 Test Probes
  • AC285 Alligator Clips
  • User manual
  • 3 year warranty

 

 

 

 

 

 

 

-------------------------------------------

 

 

 

------------------------------------------------------