Measurement & Analysis Instruments and Electrical Instruments/Power Meters, GF438II Handheld Power Analyzer thermal analyzer

category: Power Meters

reference price:¥$10,985.00

Purchase quantity
- +

Beijing GFUVE Electronics Co., Ltd.

Mr. Huang
Product details Company introduction
Parameter information

Features

Troubleshoot real-time: Analyze the trends using the cursors and zoom tools-even while background recording continues.
Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV
Measure all three phases and neutral: With included four current probes
System-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standard
View graphs and generate reports: With included analysis software
Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals.
Mains signaling: Measure interference from ripple control signals at specific frequencies
Inrush mode: For troubleshooting nuisance circuit breaker tripping.
AutoTrend: Every measurement you see is always automatically recorded, without any setup.
Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard.
Battery Life: Seven hours operating time per charge on NiMH battery pack
High safety rating: 600 V CAT IV/1000 V CAT III rated for use at the service entrance

• Comparing to online power quality analyzer, E6000 handheld type with small size, light weight, easy for the engineer to carry and carry out to survey work whenever and wherever.

 • Easy to wiring

 • It can operate directly to the line under test under the circumstances that the Power Grid without interrupt.

 • Multi-range current switching

 • based on actual demand, the different range of current clamp can be replaced to improve measurement accuracy.

Applications

Frontline troubleshooting - quickly diagnose problems on-screen to get your operation back online
Predictive maintenance - detect and prevent power quality issues before they cause downtime
Quality of service compliance - validate incoming power quality at the service entrance
Long-term analysis - uncover hard-to-find or intermittent issues
Load studies - verify electrical system capacity before adding loads
Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices.

Photos

PARAMETERS

Electrical parameters
Voltagerms, ava, pk+, pk-, rms-1/2, CF
FrequencyFreq
Currentrms, ava, pk+, pk-, rms-1/2, CF
Power & energyP, S, Q, PF, DPF, W
ComputationTHD, DC, 1-50 Harm, 1-50 InHarm, 1-35 HiHarm, 1-50 SubHarm
Voltage harmonicTHD, DC, 1-50 Harm, 0-49 InHarm, 1-35 HiHarm, 1-50 SubHarm , KF
Current harmonicTHD, DC, 1-50 Harm
Harmonic powerIa, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
Fluctuation and flickeringPST, PLT, Fluct, Fluct Max
UnbalV Pos, A pos , V neg , A neg , V zero, A zero, Unbal
Event logVoltage swell, voltage sags, DIP, surge current, voltage and current distortion out of limit, odd harmonics containing rate out of limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation
P, Q, S name
Measurement typesP: Calculate by every 10 cycles
S: Calculated by the effective value of voltage and current
Q: Calculated by the apparent power, active power
DisplayTable charts, trend chart
Measuring range/resolutionAccording to the range of the voltage and current
measuring accuracy±0.5% 
Arms
Measurement modeCalculated by the square root value of 10 cycle
Display modeEffective current value of each channel
Measuring range/resolutionCurrent: according to the current clamps
Option:5A/50A/100A/500A
Current clamps: 1200A/3000A/6000A(Flexible Current Clamp)
Accuracy0.1% + accuracy of the current clamps
Frequency
Measurement modeCalculate by 10 cycles (50Hz) or (60Hz)
Display modeMeasurement by 10 cycles
Nominal frequency/resolution50.000Hz/0.001Hz or 60.000Hz/0.001Hz
Bandwidth measurement42.5-57.5Hz or 52.5-67.5Hz
Measurement accuracy±0.001Hz
Half-wave RMS current/voltage
Measurement modeCalculate by every 2 cycles. Each cycle ,1/2 cycle made up of a waveform calculation
Measuring range/resolutionVoltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V,Current: According to the current clamps
measurement accuracy±0.1%
Vrms
Measuring circuit1P2W/ 2P3W /3P3W/ 3P4W
Basic frequency of the measuring circuit50Hz
Input channels4 phase voltage, 4 phase current
Measurement rangeVoltage measurement range: standard: 120V, 230V, 400V, 1000V, Max 1000V instantaneous voltage
Current measurement range: according to the current clamps, only support the v signal output current clamp
Power factor
Measurement modeThe ratio of average power to apparent power
Display modeReal-time data showed
Measurement range/resolution-1.000-1.000/0.001
Measurement accuracy±1% 
Vfund, Afund, Harmonic power
Measurement modeMeet IEC61000-4-7,Analysis time window is ten cycles
Window points5120 points
Display modeForm figure, trend charts, histograms
Number of measurement1-50 Times
Measurement accuracyVfund >1%: Error<1% 
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1% 
Afund <3%: Error<0.05% Current range
InHarm Voltage, InHarm current
Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
Window points5120 points
Display modeForm figure, trend charts, histograms
Numbers of measurement1-16 groups
Measurement accuracyVfund >1%: Error<1% 
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1% 
Afund <3%: Error<0.05% Current range
HiHarm Voltage, HiHarm current
Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
Window points5120 points every 10 cycles
Display modeForm figure, trend charts, histograms
Numbers of measurement1-35 groups
Measurement accuracyVfund >1%: Error<1% 
Vfund <1%: Error<0.05% rated voltage
Afund >3%: Error<1% 
Afund <3%: Error<0.05% current range
Voltage SubHarm Current SubHarm
Measurement modeMeet IEC61000-4-7, analysis time window is ten cycles
Window points5120 points every 10 cycles
Display modeForm figure, trend charts, histograms
Numbers of measurement1-50 groups
Measurement accuracyVfund >1%: Error<1% 
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1% 
Afund <3%: Error<0.05% Current range
Voltage/current Unbal (pos, neg)
Measurement mode3P3W or 3P4W, using three phase of fundamental wave components to calculate
Display modeForm figure, trend charts, histograms
Measurement accuracyVoltage unbal: ±0.2%
Current unbal: ±0.5%
Voltage fluctuation
Measurement modeCalculate by the quadratic mean of half wave.
Display modeForm figure, trend charts
Measurement accuracy±1%
IEC Flickering
MeasurementP short term (Pst) , P long term (Plt) 
Measurement modeAccording to IEC61000-4-15 Standard to calculate Pst (10 mins) Plt (2 hours) 
Display modeForm figure, trend charts
Measurement range0-20
Measurement accuracy±5%
Surge current
Measurement modeHalf-wave RMS of current is higher than set value and sustain time is 10ms-1min
Display modeMaximum of the surge current and surge current wave
Measurement accuracy0.10%
Voltage swell, Voltage sags, DIP
Measurement modeSwell: When half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as swell.
Sags: When half-wave RMS of voltage is lower than set value and sustain time is 10ms-1min, judged as sags.
DIP: half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as DIP
Display modeSwell, sags, DIP wave sustain time, extent and so on.
Measurement accuracy0.10%
Machinery
Size263mm x 168mm x 65mm
Weight2KG
Power supply
Voltage input110V-240V 
Adapter output15V, 3A
BatteryRechargeable nickel metal hydride, 4500mAh
Battery working time4h
Battery recharging time5h (Environment temperature 25°C)
Power saving facilityLCD backlight brightness is adjustable, standby time is adjustable
Display
Size112.8 x 84.6mm
Color260000 color
Resolutions640 x 480
BrightnessMax 350 cd/m2 (Typ), brightness is adjustable
Contrast500:1 (Typ) 
Visual angle70/70/50/70 (Typ.)(CR ≥10) ( Left/ Right/ UP/Down)
Store
TypeTF card (inbuilt) 
Size8G
Standards
Measurement methodIEC 61000-4-30
Measurement performanceIEC 61000-4-30 A LVL
FlickeringIEC 61000-4-15
HarmonicIEC 61000-4-7
Safety
Standard GB 4793.1-2007/IEC 61010-1:2001: "Measurement, control and laboratory electrical equipment safety requirements", first part: general requirements. 
Security level: CAT III 1000 V/ CAT IV 600 V.
MAX voltage of phase angle inputCAT III 1000V/CAT IV 600V
Environmental conditions
Working environment0°C to +45°C, humidity below 90rh% 
Storing environment-20°C to +50°C, humidity below 95rh% (non-condensing)
 