category: Circuit Breakers
reference price:¥$6.29 - $7.78
Type | AOM-125S | AOM-125M | AOM-125H | AOM-160S | AOM-160M | AOM-160H | ||||||
Pole | 1P,2P,3P,4P | 2P,3P,4P | ||||||||||
Rated current(A) | 16,20,32,40,50,63,80,100,125 | 16,20,32,40,50,63,80,100,125,140,160 | ||||||||||
Rated voltage | AC 400V | AC 400V | ||||||||||
Rated insulation voltage | AC 1000V | AC 1000V | ||||||||||
Short-circuit breaking capacity(KA)Icu/Ics | AC 400V | 25/15 | 36/18 | 50/50 | 30/15 | 36/18 | 2P:30/50 3P/4P:50/50 | |||||
Operating cycle number | ON | 6000 | 3000 | |||||||||
OFF | 9000 | 7000 | ||||||||||
Outline dim. (mm) a-b-c-ca | 1P | 25-130-68-90 | / | / | / | |||||||
2P | 50-130-68-90 | 60-155-68-90 | 60-155-68-90 | 60-155-88-115 | ||||||||
3P | 75-130-68-90 | 90-155-68-90 | 90-155-68-90 | 90-155-88-115 | ||||||||
4P | 100-130-68-90 | 120-155-68-90 | 120-155-68-90 | 120-155-88-115 | ||||||||
Weight (kg) | 1P | 0.25 | 0.3 | / | / | / | ||||||
2P | 0.5 | 0.55 | 1.0 | 1.1 | ||||||||
3P | 0.55 | 0.65 | 1.1 | 1.2 | ||||||||
4P | 0.65 | 0.8 | 1.4 | 1.5 | ||||||||
Electric operating device (MD) | ● | ● | ||||||||||
External driving operating handle | ● | ● | ||||||||||
Automatic release | Thermal electromagnetic type | Thermal electromagnetic type |
Type | AOM-250S | AOM-250M | AOM-250H | AOM-400S | AOM-400M | AOM-400H | ||||||
Pole | 3P,4P | 3P,4P | ||||||||||
Rated current(A) | 100,125,140,160,180,200,225, 250 | 250,315,350,400 | ||||||||||
Rated voltage | AC 400V | AC 400V | ||||||||||
Rated insulation voltage | AC 1000V | AC 1000V | ||||||||||
Short-circuit breaking capacity(KA)Icu/Ics | AC 400V | 32/25 | 50/35 | 65/50 | 50/35 | 65/42 | 65/65 | |||||
Operating cycle number | ON | 3000 | 2000 | |||||||||
OFF | 7000 | 4000 | ||||||||||
Outline dim. (mm) a-b-c-ca | 3P | 105-165-68-92 | 105-165-88-115 | 140-257-103-155 | ||||||||
4P | 140-165-68-92 | 140-165-88-115 | 184-257-103-155 | |||||||||
Weight (kg) | 3P | 1.5 | 1.7 | 5.5 | ||||||||
4P | 1.9 | 2.1 | 5.5 | |||||||||
Electric operating device (MD) | ● | ● | ||||||||||
External driving operating handle | ● | ● | ||||||||||
Automatic release | Thermal electromagnetic type | Thermal electromagnetic type |
Type | AOM-630S | AOM-630M | AOM-630H | AOM-800S | AOM-800M | AOM-800H | ||||||
Pole | 3P,4P | 3P,4P | ||||||||||
Rated current(A) | 500,630 | 500,630,700,800 | ||||||||||
Rated voltage | AC 400V | AC 400V | ||||||||||
Rated insulation voltage | AC 1000V | AC 1000V | ||||||||||
Short-circuit breaking capacity(KA)Icu/Ics | AC 400V | 50/35 | 65/42 | 65/65 | 50/35 | 65/42 | 70/70 | |||||
Operating cycle number | ON | 2000 | 1500 | |||||||||
OFF | 4000 | 4000 | ||||||||||
Outline dim. (mm) a-b-c-ca | 3P | 140-257-103-155 | 210-275-103-155 | |||||||||
4P | 184-257-103-155 | 210-275-103-155 | ||||||||||
Weight (kg) | 3P | 5.7 | 9.5 | |||||||||
4P | 7.5 | 12.5 | ||||||||||
Electric operating device (MD) | ● | ● | ||||||||||
External driving operating handle | ● | ● | ||||||||||
Automatic release | Thermal electromagnetic type | Thermal electromagnetic type |