Categories

MCCB YUYE YEM3-400 Professional Factory price list mccb schneider Moulded case circuit breaker

category: Circuit Breakers

reference price:¥$69.63 - $83.62

Purchase quantity
- +

One Two Three Electric Co., Ltd.

Ms. Chen
Product details Company introduction
Parameter information

Product details

Name

Details

Enterprise code

Shanghai Yuhuang Electric Co.,ltd

Product category

Moulded case circuit breaker

Design code

3

Current rank

125,160,250,400,630,800

Breaking capacity

L=economical type,M=standard type,H=high score type

pole

3P,4P

Part NO.

300 No part(Please see the release part NO.table)

Rated current

10A~800A

Operation type

None=Manual direct operation P=Electric operation Z=Manual manipulation

Use NO.

None=Power distribution type breaker 2=Protect motor

N pole shape

Four poles products N polar form:

A  type:N polar do not install over-current release,and N polar does not open and close together with other three.

B type :N polar do not install over-current release,and N polar opens and close together with other three polars

C type :N polar installs over-current release,and N polar opens and closes together with other three polars.

D type :N polar installs over-current release,and N polar electrifies all the time, at the same time,N polar does not open and closes together with other three polars.

Writing type

None=None(front writing),R(Back board writing),PR(plug-in)

 

 

Product summary

  YEM3 series moulded case circuit breaker(hereinafter referred to circuit breaker)is applied in the circuit of AC 50/60 HZ,its rated isolation voltage is 800V,rated working voltage is 415V,its rated working current reaches to 800A ,it is used to transfer infrequently and infrequent motor start(Inm<=400A).Circuit breaker has over-load,short circuit and under-voltage protection function so that protects the circuit and power supply device from being damaged.This circuit breaker has the features of small volume,high breaking ability,short arc and anti-vibration.

Circuit breaker can be installed vertically or horizontally.

 

Operating conditions

1. Altitude:<=2000m.

2. Environmental temperature:-5~+40.

3. The relative humidity of the air does not exceed 50% at a maximum temperature of +40,higher relative humidities may be permitted at lower temperature,e.g.90% at 20.Special measure may be necessary in case of occasion condensation due to variations in temperature.

4. Pollution degree 3.

5. Installing category:for main circuit,for other auxiliary and control circuits.

6. The circuit breaker is suitable for the electromagnetic environment A.

7. There must be not any explosive dangerous and not any conducting dust,there must be not any gas which would corrode metal and destroy insulation.

8. The place would not by invaded by rain and snow.

9. The storage condition:the air temperature is -40~+70.