category: Inverters & Converters
reference price:¥$856.00 - $878.00
Standards compliant | In line with national standards: (GB14048.6-98) |
Three-phase power | Voltage (AC) 380V ± 15% |
frequency | 50Hz/60Hz |
Applicable motor | Squirrel-cage three-phase asynchronous motor |
Starting frequency | Recommended no more than 20 times per hour depending on load conditions |
Protection level | IP (available) |
Impact resistance | 15gms |
Seismic resistance | The altitude is below 3000, and the vibration intensity is below 0.5G. |
Ambient temperature | Operating temperature 0 °C ~ +40 °C without derating (+40 ° C ~ 60 ° C, for every 1 ° C increase, the current is reduced by 2%) |
Storage temperature | -25℃~70℃ |
environment humidity | 93% non-condensing or dripping |
Maximum work | No derating within 1000 meters (100 meters or more, for every 100 meters, the current is reduced by 5%) |
cooling method | Natural cold wind |
Relative to vertical | Maximum working angle for vertical position is not required |
Itmes | Description | ||||||
Product Name | Three Phase 15kw to 630kw Motor Soft Starter | ||||||
Model | SJR3-3200-4 | ||||||
Power | 200kw | ||||||
Rated Voltage | 380V±15% | ||||||
Rated Frequency | 50HZ/60HZ | ||||||
Applicable motor | Squirrel-cage three-phase asynchronous motor | ||||||
Application scenario | Compressors, fans, pumps, conveyors, crushers, turbo blowers, axial fans, mixers, construction cranes, etc. | ||||||
OEM&ODM | Acceptable |
Soft starter 230V/400V/660V-50/60Hz | Motor rated power | ||||||
Soft starter model | Class 10 maximum allowable current (A) | 220V | 380V | 660V | |||
SJR3-3018 | 38 | 9KW | 18.5KW | 30KW | |||
SJR3-3022 | 44 | 11KW | 22KW | 37KW | |||
SJR3-3030 | 60 | 15KW | 30KW | 45KW | |||
SJR3-3037 | 74 | 18.5KW | 37KW | 55KW | |||
SJR3-3045 | 100 | 22KW | 45KW | 75KW | |||
SJR3-3055 | 110 | 30KW | 55KW | 90KW | |||
SJR3-3075 | 150 | 37KW | 75KW | 115KW | |||
SJR3-3090 | 160 | 45KW | 90KW | 132KW | |||
SJR3-3115 | 200 | 55KW | 115KW | 160KW | |||
SJR3-3132 | 250 | 75KW | 132KW | 200KW | |||
SJR3-3160 | 300 | 90KW | 160KW | 250KW | |||
SJR3-3200 | 360 | 115KW | 200KW | 355KW |
KEY | MAIN FUNCTION | |||
RUN | When it shows Ready,press this button to start and show Start -0000. | |||
STOP | During normal operation, display A0000 (Current value). Press Stop for soft parking,it shows 0000. This button also can reset fault status. | |||
SET | When it shows Ready,press this button can enter Menu Settings. Display F0:40 and press this button again. If the colon flashes at this time, you can press the Up &Down Keys to modify the parameters. | |||
YES | After modifying the parameters, press this button to save.When it displays good and sound two times, the identification data has been stored, and then press this button or stop button to exit. Press this button and display the input power voltage.For details on AC380, see page 3-2 and press the YES button to power up, so that the setting parameters can be restored to the factory defaults. | |||
UP&DOWN KEYS | Enter the menu to set the case and modify parameters. (When the colon does not flash, this button modifies the function code; when the colon flashes, this button modifies the data code). During operation, this button can observe the running A current, P power and H overload thermal balance display. | |||
The keyboard panel can be removed, (for operation outside the cabinet) the lead distance is less than three meters. |
Application type | Load type | SJR3 performs functions | Starting current% | Start time (seconds) |
Centrifugal pump | Slow stop protection (eliminating water hammer), underload protection or protection against phase reversal. | 300 | 5-15 | |
Piston pump | Standard load | Test run. Controls lubrication-free operation and pump rotation direction. | 350 | 5-15 |
Standard load, if >30S is overloaded | Detects the process or underload caused by the obstruction and provides the braking torque at the time of shutdown. (motor fan drive is interrupted) | 300 | 10-40 | |
Cold shrinking machine | Standard load | Motor protection, available for special motors | 300 | 5-10 |
Screw compressor | Provides protection against phase reversal and contacts for automatic draining during shutdown | 350 | 3-20 | |
Centrifugal compressor | Standard load, if >30S is overloaded | Provides protection against phase reversal and contacts for automatic draining during shutdown | 300 | 10-40 |
Piston compressor | Provides protection against phase reversal and contacts for automatic draining during shutdown | 350 | 5-10 | |
Transfer belt/moving machine | Process control to detect faults or underload control to detect open circuits | 350 | 3-10 | |
Spiral crane | Standard load | Process control to detect harsh environments. | 300 | 3-10 |
T-type cable car | Standard load | Detect blocked overload control. | 300 | 2-10 |
elevator | Standard load | Detect blocked overload control. Constant starting of varying loads. | 400 | 5-10 |
Circular saw / band saw | Standard load | Quick stop brake | 300-350 | 5-60 |
Crusher/ chipper | Heavy load | Control starting torque | 400 | 3-10 |
Mixer(large) | Standard load | The current display indicates the product density. | 350 | 5-20 |
Mixer(small) | Standard load | Current display. | 350 | 5-10 |
Grinder | Heavy load | Limit vibration during shutdown and detect blocked overload control. | 450 | 5-60 |
Crusher | Standard load | Limit vibration during shutdown and detect blocked overload control. | 400 | 10-40 |
Refiner | Standard load | Control start and stop torque. | 300 | 5-30 |
Press | Heavy load | Increase the duty cycle of the brakes. | 400 | 20-60 |
Detect blocked overload control or detect underrun control of breakpoints. | 400 | 2-10 | ||
Detect blocked overload control or detect underrun control of breakpoints. | 300 | 3-10 | ||
Detect blocked overload control or detect underrun control of breakpoints. | 400 | 2-10 | ||
Detect blocked overload control or detect underrun control of breakpoints. | 300 | 3-10 |
Q1: Are you a manufacturer or trading company?
A: We are a Variable frequency inverter manufacturer.
Q2: Can you accept to use our logo?
A: we accept OEM production.
Q3:How can i get the after-service?
A:We' have more than 10 years experience in this field. If there's any problem, please feel free to contact us, we'll provide suggestion from our engineer to help you solve the problem.
Q4: What is your terms of payment ?
A:We accept T/T, L/C,paypal, western union,etc.The details you can discuss with us.
Q5:Do you provide warranty for the goods?
A: Yes, we provide 18 months of warranty for all the goods from us.
Q6: How about your products quality inspection?
A: We have professional QA and QC teams, 100% quality inspection is performed before goods out of factory.
Q7.Is your company certified?
A: We have CE,ISO9001, CQC, Patent Certificate.